– 77 –
)UHH]HUDQG)UHVK)RRG'UDLQ7UDS7XEHV
The freezer and fresh food drain trap tubes
connected inside the cabinet and exit through a
common drain outlet tube.
A check valve is located between each drain outlet
tube and each drain trap tube.
Each drain trap tube can be removed by pulling it
GRZQDQGRȺWKHFKHFNYDOYH7KHFKHFNYDOYHFDQ
WKHQEHSXOOHGRȺWKH
evaporator drain tube.
&DXWLRQ
An improperly assembled drain trap tube
and check valve can result in a distorted check valve
UHVXOWLQJLQZDWHURYHUÀRZLQJWKH
evaporator drain
trough. To ensure the check valve functions properly,
the check valve must be installed onto the drain trap
WXEH¿UVWDQGWKHQDWWDFKHGWRWKH
evaporator drain
outlet tube at the bottom of the cabinet.
'DPDJHG&KHFN9DOYH*RRG&KHFN9DOYH
(Continued next page)
Check V
alve
Drain Outlet Tube
Drain Tube
Disconnect
Rubber Grommet (behind bracket)
1/4" Screw
Disconnect
&RQGHQVHU)DQ
The condenser fan is located in the machine
compartment between the 3-way valve and the
condenser.
The condenser fan will operate at 1000 RPM –2100
RPM with RPM feedback to the control.
&RQGHQVHU)DQ5HPRYDO
1. Remove the machine compartment cover (see
the Machine Compartment Cover section).
2. Remove the 1/4 in. hex head screw that
attaches the 3-way valve bracket and rubber
grommet to the refrigerator.
3. Carefully reposition the 3-way valve and drier
to gain better access to the condenser fan and
valve wire harnesses.
4. Disconnect the wire harness attached to the
back of the 3-way valve coil.
5. Disconnect the fan and valve wire harness from
the cabinet.