– 121 –
)DXOW&RGH
'LVSOD\HG
)DXOW&RGH'H¿QLWLRQ
6HWWLQJ&ULWHULD
F700
7 0 0
Stuck keys On ICID/ACM/
(Dispenser Boards)
Stuck Key is present on ICID/
ACM. Only send once per each
stuck key.
F701
7 0 1
Stuck keys on Internal Temp
Board
Stuck Key is present on Internal
Temp.Only send once per each
stuck key.
F702
7 0 2
Stuck keys on Deli Pan
Stuck Key is present on Deli Pan.
Only send once per each stuck
key.
F703
7 0 3
Key inputs on Temp Board and
Door Closed
FF Door is closed and a key input
is detected.
F704
7 0 4
Key inputs on Deli Pan Board
and Door Closed
FF Door is closed and a key input
is detected.
F705
7 0 5
$XWR¿OOFRPPXQLFDWLRQHUURU
AutoFill Module not
communicating properly.
F706
7 0 6
$XWR¿OOZURQJYHUVLRQ
7KHYHUVLRQRIWKH$XWR¿OO
module is not compatible with
the ACM version.
F707
7 0 7
ACM/Comm communication
error
COM module not communicating
properly.
F708
7 0 8
COM wrong version
COM version is not compatible
with the ACM.
F709
7 0 9
Cold Water Cup Switch input
missing and 0x70 message is
received from COM (ACM Only)
Dispense message is received
and 30 seconds later the Cup
Switch input is still not present.
F710
7 1 0
Cold Water Cup Switch input
present and no dispense
message is received from COM
(ACM Only)
Cup Switch input is present for
30 seconds and no dispense
message has been received.
F711
7 1 1
Hot Water Cup Switch input
missing and dispense message
is received that requires the cup
switch (ACM Only)
Dispense message is received
and 30 seconds later the Cup
Switch input is still not present.
F712
7 1 2
Hot Water Cup Switch input
present and no dispense
message is received (ACM Only)
Cup Switch input is present for
30 seconds and no dispense
message has been received.
F713
7 1 3
FF Door open for 15 minutes
without closing
Usage or door switch.
F714
7 1 4
FF Door open for 60 minutes in
the last 24 hours
Usage or door switch.
F715
7 1 5
50 FF Door openings in the last
24 hours
Usage or door switch.
F716
7 1 6
FZ Door open for 15 minutes
without closing
Usage or door switch.
,QWHUDFWLRQ