Commissioning
Commissioning the control unit
7160-9001-560
01. December 2020
Aufforderun
erscheint
4. Right-click on the component to be installed
Example: EtselVPU
- Context menu appears
5. Select menu option
(Install Device)
- The prompt appears:
"Press the service PIN"
6. Activate the service PIN on the control unit
SP
Service PIN
OF
ON
Send service PIN
DPNet service PIN
- The IP address and section are transferred
The section is set using the last two digits of the IP address.
Examples
Barn equipment
Default setting
IP address
Section
1. Milking parlour
Separates Steuergerät je
Melkstand
XXX.YYY.ZZZ.121
21
2. Milking parlour
XXX.YYY.ZZZ.122
22
1. Animal segregation
XXX.YYY.ZZZ.111
11
2. Animal segregation
-
if assigned to a separate control unit
-
Setting: 999/910/002 >1
XXX.YYY.ZZZ.112
12
Per place identification (PPID)
XXX.YYY.ZZZ.101
01
DairyRobot R9500
XXX.YYY.ZZZ.1xx
01 (-09)
- Behaviour component "DPNet" is created
The control unit communicates with the herd management system via the
"DPNet" behaviour component.
- The installation status is displayed
S9 = Installation successful
S9
Important!
If the installation status "S9" is not reached, the installation is not
complete.
► Nevertheless, continue and complete the installation.
► Eliminate the cause of incomplete installation after installation
(See related section)
- After the installation, the component is highlighted in grey and marked with
a green check mark.