Commissioning
Basics of commissioning
7160-9001-560
01. December 2020
Menu structure (VP8002)
Please note
The menu displayed depends on the version of the program installed.
Menu level
function
Comment
1
2
3
4
SP
Service PIN
depending on the
application
n
Show serial number
(last 4 digits)
Y
Send service PIN
DPNet service PIN
Ad
dA
Show address
(shows the actual address)
Device address
SA
Set address
A control unit always has the logical address 01.
(Change the address)
Setting the address
dS
Show section
(Show section)
SS
Change section
(Change section)
IP
Network settings (Ethernet)
dh
DHCP - Communication protocol
on
DHCP on
IP address assigned
automatically
oF
DHCP off
Fixed IP address
(manual)
di
Display IP address
Show IP address
Si
Set IP address
Set the IP address
nI
Set the selected address range
192
.168.1.101
N2
Set the selected address range
192.
168
.1.101
N3
Set the selected address range
192.168.
1
.101
N4
Set the selected address range
192.168.1.
101
Ai
Accept IP address
Save IP address
dn
Display network mask: 4 / 16 / 24
Show network mask
The setting is only
displayed when:
DHCP = off
Sn
Set network mask 4 / 16 / 24
Set network mask
8 = 255
.0.0.0
16 = 255
.255.0.0
24 = 255
.255.255.0
It
dE
Display fault code and clear from display afterwards
(Shows error code and error clearing after showing)
LI
L1 test output 1
L2
L2 test output 2
L2 test output 2
iI
Test input 1
I2
Test input 2
dF
00
99 is the value entered to restore the factory settings
(Empty database and IP address 192.168.1.100)
Important!
After resetting the control unit to the default settings, the control unit must be re-licensed,