Mounting the Control Top to Different Valves
Mounting to VESTA Valve H_A
78
Operating Instructions · Control Top T.VIS
®
M-15
Edition 2017-10-16
Mounting to VESTA Valve H_A
Requirement:
Pay attention not to kink the air hoses when mounting the control top.
IMPORTANT NOTE
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
Protect the permanent magnet against impact stress.
IMPORTANT NOTE
Magnetic fields resulting from the permanent magnet on the switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or mechanical
components.
Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Place O-rings (139.2) in the adapter (139) at the bottom side of the thread (139.1).
2.
Screw the adapter into the actuator (A4.1) and tighten using an open end spanner.
3.
Complete the T.VIS mounting base (198) with O-rings (29, 101) and a plain bearing
(202).
4.
Screw the mounting base (198) into the actuator (A4) and tighten using a face
spanner.