Installing the motor, motor stool and pump shaft
Wet the other threads of the pipes (0736.04) and
(0736.05) with Loctite 243 (medium strength) and
connect it with the seal cartridge (0491.00).
Fig.31:
Seal cartridge
Grease the centring for holding the motor stool at
the motor flange and grease the screw connection
with Klüber paste.
Push the motor stool (0340.00) onto the shaft
(0211.00) and fasten it with the hex head bolts
(0901.50), washers (0554.74) and (0554.75) and
hexagon nuts (0920.09) to the motor flange.
Torques:
M10 - 35 Nm
M12 - 65 Nm
M16 - 100 Nm
Fig.32:
Motor stool
Push the mounting sleeve onto the shaft (0211.00)
and position the clamp connection.
Fig.33:
Mounting sleeve
Screw on the impeller nut (0922.00) without the O-
ring seal and tighten. This sets the correct length
of the shaft.
Fig.34:
Pump shaft
Malfunctions / repairs
Repair
BA.H2A.KYY.001.GB_2
27.02.2018
57