28
Contractor’s manual
F15 - F30 Generators
Manual For F15 and F30 - Mill.: 2008 - 11 / Mod.: JPM 05
Page
12.2 Routine maintenance
12.2.2 Descaling
- Stop the machine or isolate the supply to the terminal
box.
- Pour a measure of the descaler into the base tank in
accordance with the table.
- Top up with water to reach the overfl ow of the base.
- Start the reducer and the pump only for about 1 to 2
hours according to scaling.
-
Stop operation, drain and rinse 2 or 3 times while
restarting the reducer and the pump.
Recommended descaling products
- PR 5200 ST (France)
A technical data sheet accompanies each container, giving
instructions for use.
THE INSTRUCTIONS MUST BE READ BEFORE USE.
Average dosage 7%
Important
Take care that the descaler does not fall into the ice
storage container.
Routine maintenance
With time, certain problems can arise with the operation
of the ice machine associated with the water quality.
The two main sources of problems are scaling and prolif-
eration of micro-organisms.
In addition to the potential risks associated with public
health, in both cases the operation of the ice machine can
be seriously affected.
We therefore recommend a range of products for descal-
ing and attacking micro-organisms.
Important
15.2.1 Anti-micro organism product
PR 61 is an anti-algae sanitary decontaminant product
for any microbial contamination.
It is in the form of a clear liquid.
- Density 1.02.
- PH 7.
It is sanitary and not dangerous to use.
It is not volatile.
It is rapid and works on any surface.
It has great powers of decontamination.
It can be added to a sanitary descaler to act as both a
descaler and decontaminant.
It halts corrosion of the walls of systems attacked by
microbial corrosion.
PR 61 consists of dimethyl benzyl ammonium chloride.
This type of cationic detergent is authorised in annex 1,
an approved product for cleaning equipment that may
come into contact with foodstuffs. Decree of 27 October
1975.
We test all our products ourselves to ensure they
meet all reliability criteria in terms of effectiveness
and compatibility with GENEGLACE machines.
The use of other products (for example : hydro-
chloric acid) will cause irreparable damage to
the generator.
For purposes of good hygiene and correct operation,
external cleaning of the generator assembly is essen-
tial. Dusting before washing by hand is recommended,
in order to prevent bacteria from multiplying. Do not use
a water jet, or high pressure washer.
GENERATOR F15
F30
PACK 10/12
13/14
QUANTITY (kg)
0.3
0.5