Fig.37
Carry out the following steps:
1.
Change the five O-rings (42) of the base (5).
2.
To fit the pneumatic block:
- for version 2PV (1x solenoid valve 24VDC/NO to Y2 and 1x valve plate to
Y3), see Figure 31
- for version 3PV (1x solenoid valve each 24VDC/NC to Y2 and Y3), see
Figure 32
3.
Insert the pneumatic block (8) in the base (5) and heed the positioning aid on
the screw dome (8.1).
4.
Tighten the pneumatic block (8) using 3x screws (57) in the base (5):
tightening torque 1.5 Nm (1.0 lbft)
®
Done
10.5.9 Install pneumatic connections
Maintenance
Dismantling the Control Top into its Components