8.
Check hood and base for firm screws. Tighten all three screws to 1 Nm if
necessary.
10.2.2 Servicing intervals
To ensure the highest operational reliability, all wearing parts should be replaced
at longer intervals.
The actual servicing intervals can only be determined by the user since they
depend on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Servicing intervals
Applications
Servicing Intervals (Guideline
Values)
Media at temperatures 60 °C to 130 °C
(140 °F to 266 °F)
approx. every 3 months
Media at temperatures < 60 °C (< 140
°F)
approx. every 12 months
10.2.3 Signs on the control top
Carry out the following steps:
1.
Check signs on the control top. See also Section 2.8.1, Page 12.
2.
Replace damaged or missing labels by new labels.
®
Done
10.3
Tool
List of tools
Tool
Material no.
Jaw plug-in tool 2-24 mm
408-433
Socket for wrench 3/8" 17 mm
408-444
Face spanner, adjustable 80/5 for torque wrench
408-448
Torque wrench bit D 6.3 1-5 Nm
408-449
Torque wrench plug-in 2.5 2.5 - 25 Nm
408-450
Plug-in tool square 1-1/2"
408-451
Jaw plug-in tool 1-13 mm
408-452
Maintenance
Tool