6.6.1
Fitting to FLOWVENT Valves
Fig.25
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Insert the O-rings (54) into the upper and lower O-ring groove of the
installation base.
2.
Insert the O-ring (31) on the underside (thread side facing actuator) of the
installation base
3.
Lightly grease the O-rings (54, 31) and the inner thread of the installation
base and then screw the installation base onto the actuator and tighten using
a pin-face spanner and a torque of 20 Nm. When setting the torque heed the
correction factor of the plug tool. If the plug tool (408-451) is used, the torque
to be set is 15 Nm.
4.
Screw switch bar (1) into the actuator and tighten with SW 13, torque 2 Nm
(1.4 lbft).
5.
Fit the control top (B) over the switch bar (1) onto the installation base and
push until stop. For optimum assembly the O-rings (54) should be slightly
greased.
6.
Turn the control top into the required position and tighten the two hexagon
socket screws (51) at the side to 3 Nm (base/ installation base).
Assembly and installation
Mounting the Control Top to FLOWVENT actuators
430BAL014912EN_3