Components
Room Cabinet
The room cabinet houses the reversible discharge
louvers and the air fi lters. The room cabinet snaps in
place at the top and bottom of the chassis.
REMOVE
INSTALL
Louvers
Zoneline air conditioners discharge air from the top
of the unit through reversible, 2-position discharge
louvers. The unit is shipped from the factory with the
discharge louvers at an angle of 40° off vertical. In
the alternate position, the louvers will be at an angle
of 50° off vertical.
High Wall Mount Applications
For units mounted high in the wall, the discharge
louvers should be at a setting that provides the
most horizontal air discharge. Recommended
installation is at least 3 inches below the ceiling. In
installations where units are close to the ceiling, the
most horizontal discharge angle can be obtained
by removing the discharge grille from the room
cabinet.
40°
50°
LOUVER SCREWS
LOUVER SCREWS
To adjust air direction, remove the room cabinet
(grille). Remove the 7 louver screws that hold
the louvers in place. Flip the louver section 180°.
Replace the screws and the room cabinet.