Care and Cleaning

 

 Override 

Set this switch at FREEZE

SENTINEL and whenever the
room air temperature at the air
conditioner falls to approximately

 the unit will automatically

come on in the heating mode,

regardless of whether the On/Stop
switch has turned the air

conditioner off.

Set this switch at SET BACK and
the same thing occurs whenever
the room air temperature at the
air conditioner falls to
approximately 

The Unit Power Switch must be
at ON for the 

 Override to

operate.

Turn the air conditioner off and
remove the plug from wall outlet,
or remove fuses, or turn off
circuit breakers at the power
panel before cleaning.

If you live in an apartment, your
building management may wish to
provide these maintenance 
that are necessary for continued
peak operating efficiency of your
air conditioner.

ICR System

 5000 

models 

To insure optimum performance
of the ICR system, the condensate
pump, screens, connecting tubing,
and tray should be inspected and
cleaned if necessary prior to each
heating season.

Room Cabinet & Case

Wash the room cabinet and case
finish with mild soap or detergent
and lukewarm water.

Condenser Coils

These coils on the weather side
of the unit should be checked
periodically and cleaned if
clogged with dirt or soot from the
atmosphere. If extremely soiled,
they may need to be professionally
steam cleaned, a service available
through your GE service outlet.

Air Miter

The air filter behind the room
cabinet should be washed at least
every 

 

 or   

 as it 

cleaning.

Access to the filter is obtained by

removing the room cabinet.

Case

i

I

Room Cabinet

To remove the air filter, grasp the
pull tabs on the front of 

 

 as

shown and pull toward you until the
three tabs at the top and bottom of
the filter come out of the slots in
the chassis.

Vacuum the filter on the dirty side
or wash it 

 running water. Run

water through from the cleaner side
of the falter to drive out accumulated
dust and lint. Shake to dry.

Note: The air conditioner should
not be operated without an air filter.
Replacement filters are available
from your GE Dealer, Factory
Service Center or authorized

Customer Care” servicers.

To reinstall the air filter after
cleaning, make sure the word
FRONT on the filter is facing you.
Insert the three tabs at the top of the
filter into slots at the top of the
chassis. Press upward and insert
the tabs at the bottom of the 
into slots at the bottom of the
chassis. Then replace the room
cabinet.

To replace the room cabinet,
position slots at bottom of room
cabinet onto tabs at bottom of
chassis. Tilt room cabinet inward,
lift it slightly, and position it so
clips at top hook onto front lip of
air discharge grille. Then press
room cabinet down to secure it.

To remove the room cabinet,
grasp it at both sides, lift up and
pull forward.

5

Summary of Contents for Zoneline 4000 Series

Page 1: ... Switch 4 Freeze Sentinel 3 Heating Economy Switch 4 Indicator Lights 3 Master Controls 3 Model and Serial Numbers 2 Problem Solver 6 Repair Service 7 Room Cabinet and Case 5 Safety Instructions 2 Thermostat Control 3 Unit Power Switch 4 Ventilation Control 4 Warranty Back Cover GE W m mm Heat Pump hneline Models 4000 Seties 5000 Seties ...

Page 2: ...ribed in this Use and Care Book This air conditioner must be properly installed in accordance th the Insolation Instructions before it is used Never use an extension cord th this apptiance SAW THWE STRUCTIONS Energy Saving Tips Keep the air filter clean See instructions on page 5 For most efficient operation keep vent in closed position except when you want to let outside air enter the room Don t ...

Page 3: ...ode ON STOP opERAT oN m COOL FEAT HIGH LOW 1 AUTO ANSPEED B Master Controls Push the Operation Button once to turn the air conditioner on push again to turn it off If the unit does not operate when you push this button to start it check to see if the Unit Power Switch located behind the room cabinet is on See page 4 Slide the Selector Switch to COOL for cooling or to HEAT for heating Slide the Fan...

Page 4: ...ting Uonomy Switch and Temp Override will not function Caution The Unit Power Switch is not a power disconnect If all power must be disconnected from the unit remove the line cord plug from the wall outlet or remove the fuses or turn off the circuit breakers at the power panel 4 Fan Cycle Switih This switch is set at CONT at the factory to provide continuous fan operation in cool or heat modes If ...

Page 5: ...soiled they may need to be professionally steam cleaned a service available through your GE service outlet Air Miter The air filter behind the room cabinet should be washed at least every W days or as often as it needs cleaning Access to the filter is obtained by removing the room cabinet Case F L p i Iw d Room Cabinet To remove the air filter grasp the pull tabs on the front of th fil er as shown...

Page 6: ...r registers and cold air returns o entl ation Control maybe set at p position allowing outside air to enter the room Q The Temperature Limit Switches may be sgt at a setting other than normal This will limit the operating ranges See page 4 Position of the louvers will affect temperature See page 3 BURNING ODOR Dust accumulating on surface of heating e ement during tmnspo tion or storage AT START O...

Page 7: ...rther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations GE Appliances Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel 20 ...

Page 8: ... IS N COVERED Service trips to teach you how to Improper installation Failure of the product resulting from use the product If you have an installation modifications to the product or due to Read your Use and Care material problem or if the air conditioner unreasonable use including failure to If you then have any questions is of improper cooling or heating provide reasonable and necessary about o...

Reviews: