To maintain optimum performance, clean the filters at least every 30 days.

Air Filters

Turn the Zoneline off before cleaning.

The most important thing you can do to
maintain the Zoneline is to clean the filter 
at least every 30 days. Clogged filters reduce
cooling, heating and air flow.

Keeping these filters clean will:

Decrease cost of operation.

Save energy.

Prevent clogged heat exchanger coils.

Reduce the risk of premature component
failure.

To clean the air filters:

Vacuum off the heavy soil.

Run water through the filters from the 
back side.

Dry thoroughly before replacing.

NOTE: 

The air filters are interchangeable 

and will fit in either the right or left side.

To remove the air filters:

To replace the air filters:

CAUTION:

Do not operate the

Zoneline without the filters in place. If a filter
becomes torn or damaged, it should be replaced
immediately.

Operating without the filters in place or with
damaged filters will allow dirt and dust to reach
the indoor coil and reduce the cooling, heating,
airflow and efficiency of the unit.

Replacement filters are available from your
salesperson, GE dealer, GE Service and Parts
Center or authorized Customer Care

®

servicers.

Dirty filter—Needs cleaning 

Clogged filter—Greatly
reduces cooling, heating
and airflow.

FRONT

FRONT

Pull up

Push down

2 Air filters

Care and cleaning.

Summary of Contents for Zoneline 2900

Page 1: ...ort Consumer Support Back Cover Warranty 23 Heat Cool Model 2900 Heat Pump Model 3900 Owner s Manual and Installation Instructions ge com Write the model and serial numbers here Model ________________...

Page 2: ...ck of this manual Replace immediately all electric service cords that have become frayed or otherwise damaged A damaged power supply cord must be replaced with a new power supply cord obtained from th...

Page 3: ...o set the air conditioner to run for 8 hours before it automatically returns to the previous setting When in the cooling mode and the sleep timer is set the set temperature will automatically increase...

Page 4: ...t be removed from the vent door before use See the Installation Instructions in the back of this manual Air Direction To adjust the air direction remove the room cabinet Remove the 7 louver screws tha...

Page 5: ...es models only Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support All Electric Heat This electric heat option functions only on the 3900 Series models W...

Page 6: ...e limiting is controlled by the second six auxiliary switches The first three switches are used to select the cooling limits and the remaining three switches are used to control the heating limits Thi...

Page 7: ...an auxiliary switch for AZ2900 models and must remain in the DOWN position BOOST Heat Boost Operation Auxiliary Controls Terminal Connections The auxiliary controls are located behind the room cabine...

Page 8: ...t When connected the unit will be controlled by a remote thermostat NOTE The number 4 dip switch must be in the enabled UP position to activate the remote thermostat See the installation instructions...

Page 9: ...ent filter tab and pull the filter out by sliding it to the right To clean the vent filter Run water through the filter from the back side Dry thoroughly before replacing Outdoor Coils The coils on th...

Page 10: ...rough the filters from the back side Dry thoroughly before replacing NOTE The air filters are interchangeable and will fit in either the right or left side To remove the air filters To replace the air...

Page 11: ...or local codes and ordinances For personal safety this Zoneline must be properly grounded Protective devices fuses or circuit breakers acceptable for Zoneline installations are specified on the namep...

Page 12: ...at were not designed for your new GE Zonelines The RAK40 contains air deflectors and gaskets that mount to the unit to direct the hot exhaust air away from the air intake to allow the unit to function...

Page 13: ...ler to ensure the connection of components is done in accordance with these instructions and all electrical codes Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15 RAK204D15P 20 RAK204D...

Page 14: ...e for direct connection The instructions provided with the selected subbase kit must be carefully followed It is the responsibility of the installer to ensure the connection of components is done in a...

Page 15: ...to attach conduit coming from the branch circuit Remove the knockout attach the conduit and bring wires into the junction box Leave 6 of wire free at the end of the conduit to allow connections to be...

Page 16: ...r 5 00 4 10 KW 230 208 Volt Heater Wattage Power Supply Kits 230 208 Volts Circuit Protective Device RAK4157 2 55 KW 2 09 KW 15 Amp Time Delay Fuse or Breaker RAK4207 3 45 KW 2 82 KW 20 Amp Time Delay...

Page 17: ...ies wall cases are insulated Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed NOTE For installation with a subbase or duct adapter see the instruct...

Page 18: ...e top over the rail along the unit top 1 then pushing it in at the bottom 2 4 Installation Instructions 18 NOTE There are several extra holes in the unit side flanges for installation in wall cases ot...

Page 19: ...g onto external building walls we recommend the use of RAD10 Drain Kit External Drain See the Installation Instructions in the RAD10 kit Internal Drain See the Installation Instructions in the RAD10 k...

Page 20: ...rrupter Press the RESET button located on the power cord plug device is tripped or the box near the plug If the RESET button will not stay engaged discontinue use of the Zoneline and contact a qualifi...

Page 21: ...off the warm enough during produces air that feels heat pump and warms with electric heat only heating operation cooler than desired NOTE Use of this option will result in increased energy consumption...

Page 22: ...o hear a fan noise stop and start You may notice a few minutes delay in starting if you try to restart the Zoneline too soon after turning it off or if you adjust the thermostat right after the compre...

Page 23: ...s to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Failure or damage resulting from corrosion due to installation in a coastal environment ex...

Page 24: ...call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discov...

Reviews: