Add up total length of system

If necessary, join two strips together using a 

jump connector or a soldered wire connection. 

Follow steps 4b-6b for each end of the jump 

connection, or 4a-6a for each end of the 

soldered wire connection.

Remove tape backing and stick Tetra

®

 flexible 

tape in place. Ensure the tape is firmly attached. 
NOTE: Securing with electrical grade silicone is 

also acceptable. 
To avoid water ingress or shorting to the mating 

surface, all product should be inspected for 

breaks in the adhesive backing or silicone cover 

prior to installation and any damaged product 

should be not be installed.
Do not remove, reposition, or lift the tape once 

the adhesive backing has made contact with the 

mounting surface. 

Mounting surface

Jumper 

connector

If connector is needed, refer to steps 4b-6b

Stopper

Connector cover 

is open

Red

“Click”

+

Black

Check the connector for 

cosmetic issues. Open the 

cover. Remove the stopper 

from the tape guide.  

NOTE: If the stopper is 

missing and the connector 

cover has been locked, please 

change to another one.

Partially remove the tape 

backing on the end to be 

connected. Align red lead with 

the (+) contact on the tape 

and the black lead with the (-) 

contact. Fully insert the tape into 

the open end of the tape guide 

with the LEDs facing the cover. 

Press the cover down onto 

the tape guide until a “click” 

is heard. Visually check 

the connection for correct 

polarity, good continuity, and 

secureness.

Add up total footage of the system to 

determine the appropriate number of 12VDC 

Class 2 Tetra

®

 power supplies to use based on 

the Power Supply Loading chart on last page.

If installing multiple power supplies, keep them 

at least 2” (50.8mm) apart end to end and 4” 

(101.6mm) apart along the sides.

Electrical Connections

4”

2”

Power supply

Power supply

Power supply

Power supply

NOTE: Do not use connectors pre-filled with silicone 

grease/mineral base protective grease or use silicone 

grease to seal connections.

4b

7

1

2

8

5b

6b

Tetra

®

 LED Tape Gen 2

Installation Guide

4

Summary of Contents for Tetra GETP35-2

Page 1: ...dotyczące bezpieczeństwa można znaleźć w następującej lokalizacji https products gecurrent com eu PT A versão em Português das instruções de instalação e das informações de segurança pode ser encontrada na seguinte localização https products gecurrent com eu RO Versiunea în limba românǎ a instrucţiunilor de instalare şi a informaţiilor de siguranţǎ pot fi gǎsite la https products gecurrent com eu ...

Page 2: ...pas d installation Veuillez contacter un électricien qualifié Risque d incendie ou de choc électrique Installez cet ensemble seulement dans des enseignes hôtes qui ont été identifiés dans les instructions d installation et dont la capacité d entrée de l ensemble ne dépasse pas la capacité d entrée de l enseigne L installation de cet équipement de remplacement DEL peut impliquer le perçage ou le po...

Page 3: ...ve End cap Tape backing Silicone Clean mounting surface At the cut end carefully peel back the silicone cover over the soldering pads Make sure not to remove the silicone over the LED Using UL certified 18AWG wire solder a red wire to the pad and a black wire to the pad Heat shrink Silicone cover Red Black Seal the soldering points with electrical silicone Replace the silicone cover and secure it ...

Page 4: ...n the cover Remove the stopper from the tape guide NOTE If the stopper is missing and the connector cover has been locked please change to another one Partially remove the tape backing on the end to be connected Align red lead with the contact on the tape and the black lead with the contact Fully insert the tape into the open end of the tape guide with the LEDs facing the cover Press the cover dow...

Page 5: ...isting lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Repair and seal any unused openings in the electrical enclosure Openings greater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openin...

Page 6: ...t 9 1 m 50 ft 15 2 m 86 ft 26 2 m 180W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 2 m SKU Rating 25W Power Supply 60W Power Supply 180W Power Supply GETP35 2 GETP40 2 GETP50 2 GETP60 2 4 5W m 1 37W ft 4m 13 ft 10m 32 ft 10m 32 ft per output channel 30m 96 ft per power supply GETPH35 2 GETPH40 2 GETPH50 2 GETPH60 2 10 6W m 3 22W ft 1 7m 5 6 ft 4m 13 ft 4m 13 ft per output channel 12...

Reviews: