background image

Tc point

Installation Steps

If soldering is needed, refer to steps 4a-6a

Components

UL certified 18 AWG (0.82 mm

2

) supply wire

UL certified 22-14 AWG (0.33-2.08 mm

2

twist-on wire connectors or 18-14 AWG 

(0.82-2.82 mm

2

) inline/IDC connectors

Flexible Tape End Cap 
Tetra

®

 12 Volt Power Supply

Tetra

®  

LED Tape Gen 2

Tetra

®  

Flexible Tape Lead Connector (GETPLCN54-1)

Mounting surface must be free 

of dust, dirt or grease. Clean 

mounting surface with alcohol  

before installation and allow to dry.

Measure and cut Tetra

® 

 flexible 

tape to the desired length using 

scissors. Cut only on the scissor 

markings and stay within the 

limit lines. 

Peel away a portion of the tape 

backing at cut end. Press fit 

an end cap fully to the open 

end and apply electrical grade 

silicone (see examples above).

End cap

Tape backing

Silicone

Clean 

mounting 

surface

At the cut end, carefully peel 

back the silicone cover over the 

soldering pads. Make sure not to 

remove the silicone over the LED.

Using UL certified 18AWG 

wire, solder a red wire to the 

(+) pad and a black wire to the 

(–) pad.

Heat shrink

Silicone cover

Red (+)

Black (–)

Seal the soldering points with 

electrical silicone. Replace the 

silicone cover and secure it by 

shrinking a piece of ¼” heat 

shrink over the end.

Tetra

®  

Flexible Tape Jump Connector (GETPJCN54-1)

Scissors
Electrical grade RTV silicone. 

Example electrical grade RTV silicones include:

•  Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant

•  Momentive White Blanc RTV 162 Silicone Rubber Adhesive Sealant-

Electrical Grade

•  Dow Corning 3140 - Non-Corrosive Flowable (clear)

•  Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray)

•  Dow Corning RTV 748 Non-Corrosive Sealant-White

2

2

1

1

3

3

4

7

7

4

5

8

8

5

6

9

9

6

1

4a

5a

6a

2

3

Tetra

®

 LED Tape Gen 2

Installation Guide

3

Summary of Contents for Tetra GETP35-2

Page 1: ...dotyczące bezpieczeństwa można znaleźć w następującej lokalizacji https products gecurrent com eu PT A versão em Português das instruções de instalação e das informações de segurança pode ser encontrada na seguinte localização https products gecurrent com eu RO Versiunea în limba românǎ a instrucţiunilor de instalare şi a informaţiilor de siguranţǎ pot fi gǎsite la https products gecurrent com eu ...

Page 2: ...pas d installation Veuillez contacter un électricien qualifié Risque d incendie ou de choc électrique Installez cet ensemble seulement dans des enseignes hôtes qui ont été identifiés dans les instructions d installation et dont la capacité d entrée de l ensemble ne dépasse pas la capacité d entrée de l enseigne L installation de cet équipement de remplacement DEL peut impliquer le perçage ou le po...

Page 3: ...ve End cap Tape backing Silicone Clean mounting surface At the cut end carefully peel back the silicone cover over the soldering pads Make sure not to remove the silicone over the LED Using UL certified 18AWG wire solder a red wire to the pad and a black wire to the pad Heat shrink Silicone cover Red Black Seal the soldering points with electrical silicone Replace the silicone cover and secure it ...

Page 4: ...n the cover Remove the stopper from the tape guide NOTE If the stopper is missing and the connector cover has been locked please change to another one Partially remove the tape backing on the end to be connected Align red lead with the contact on the tape and the black lead with the contact Fully insert the tape into the open end of the tape guide with the LEDs facing the cover Press the cover dow...

Page 5: ...isting lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Repair and seal any unused openings in the electrical enclosure Openings greater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openin...

Page 6: ...t 9 1 m 50 ft 15 2 m 86 ft 26 2 m 180W Power Supply 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 86 ft 26 2 m SKU Rating 25W Power Supply 60W Power Supply 180W Power Supply GETP35 2 GETP40 2 GETP50 2 GETP60 2 4 5W m 1 37W ft 4m 13 ft 10m 32 ft 10m 32 ft per output channel 30m 96 ft per power supply GETPH35 2 GETPH40 2 GETPH50 2 GETPH60 2 10 6W m 3 22W ft 1 7m 5 6 ft 4m 13 ft 4m 13 ft per output channel 12...