GEPS24-100U-GLX

Tetra

®

 LED Systems Power Supply

24

Volt

Installation Guide

Power Supply Features

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

 CAUTION/ATTENTION

RISK OF INJURY
• While performing installations described, gloves, safety glasses  

  or goggles should be worn. 

RISQUE DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de    

  sécurité ou des lunettes de protection doivent être portées.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

This device complies with part 15 of the FCC Rules. Operation is subject 

to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.
Note:

 This equipment has been tested and found to comply with the limits 

for a Class A digital device, pursuant to part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio frequency energy 

and, if not installed and used in accordance with the instruction manual, 

may cause harmful interference to radio communications. Operation of 

this equipment in a residential area is likely to cause harmful interference in 

which case the user will be required to correct the interference at his own 

expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR 

de la classe [A] est conforme à la NMB-005 du Canada. 

Prepare Electrical Wiring

Electrical Requirements
•  Limited to use in dry and damp locations.
•  The suitability of rain enclosure shall be determined if 

intended for wet location.

•  The grounding and bonding of the LED Driver shall be 

done in accordance with National Electric Code (NEC) 
Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
•  Disconnect power at fuse box or circuit breaker before servicing 

or installing product.

•  Properly ground Tetra

®

 power supply.

•  AC input connections shall be suitably enclosed. The power 

supply shall be enclosed or made inaccessible to users during 
normal use.

RISK OF FIRE
•  Minimum power supply spacing to other power supply or other 

heat producing component shall be at least 4” (101.6 mm) from 

side to side and 1” (25.4mm) from end to end.

•  Use only approved wire for input/output connection. Minimum 

size 18 AWG (0.82 mm

2

).

•  Follow all local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES
•  Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant 

l’entretien ou l’installation du produit.

•  Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra

®

.

RISQUES D’INCENDIE
•  N’utilisez que des fils approuvés pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82 mm

2

).

•  Respectez tous les codes locaux.

•  Supports Tetra PowerStrip SS, Tetra PowerStrip DS, Tetra miniStrip DS, 

Tetra Edgestrip, Tetra Contour, Tetra Contour LS, Tetra miniMAX, 

Tetra MS, Tetra MAX, Tetra PowerMAX, Tetra PowerMAX HO and Tetra Stick 

LED lighting systems

• 

UL: Class 2 wiring per NEC Article 725, dry and damp location rated

• 

IEC: SELV, CE: IP54 rated, must be protected from direct exposure to the weather

Summary of Contents for Tetra GEPS24-100U-GLX

Page 1: ...andard ICES 005 Ce DEFR de la classe A est conforme à la NMB 005 du Canada Prepare Electrical Wiring Electrical Requirements Limited to use in dry and damp locations The suitability of rain enclosure shall be determined if intended for wet location The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes ...

Page 2: ...deral and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Make sure the removal of lighting equipment does not compromise the...

Page 3: ...450 W1 GEPM2441 W1 GEPM2432 W1 0 84W module 96 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerMAX HO GEPMH2471 W1CS1 GEPMH2450 W1CS1 GEPMH2441 W1CS1 GEPMH2432 W1CS1 1 2W module 64 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerStrip SS GESS2471 2 GESS2450 2 GESS2441 2 GESS2432 2 2 52W module 36 modules 20 ft 6 1 m 25 ft 7 6 m 35...

Page 4: ... 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF24DHOLED 1 GEF24SGNHOLED 1 GEF24CWHOLED 1 11 5W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF30DHOLED 1 GEF30SGNHOLED 1 GEF30CWHOLED 1 14 4W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF36DHOLED 1 GEF36SGNHOLED 1 GEF36CWHOLED 1 17 3W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF42DHOLED 1 GEF42SGNHO...

Page 5: ... 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06071A1 GETSPMDS06071B1 11 8 W Stick 7 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06471A1 GETSPMDS06471B1 13 4 W Stick 6 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS07271A1 GETSPMDS07271B1 15 2 W Stick 5 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS08471A1 GETSPMDS08471B1 16 8 W Stick 5 Sticks 20 ft 6...

Page 6: ...nd power supply for improper termination s or short circuits Properly terminate or replace the wire connection s Check that connections are the red striped wire of the LED strip to the red wire of the power supply and the white wire of the LED strip to the black or blue wire of the power supply Chart continued Remote Mounting Distance Supports Tetra Products SKUs Rated Power Maximum Load per Power...

Reviews: