Power Supply Installation

2

Connect the AC line to the black 

(line) and white (neutral) input 

wires of the power supply using 

suitable wire connectors.

Connect the supply wire that is 

attached to the Tetra LED System to 

the red (+) and black (-) output wires 

of the power supply as outlined in 

the “Electrical Connections” section 

of your LED system’s Installation 

Instructions.

3

Input 

wires

White (neutral)

Black (line)

AC line

To Tetra LED System

Output 

wires

Red (+)

Black (-)

NOTE: 

For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 ft. (9 m) of primary side 

of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch must also support twice the 

amount of input current.

NOTE: 

When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral 

connections, in accordance with local, state or country regulations. 

NOTE: 

The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code 

(NEC) Article 600.

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the 

building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED 

power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes 

(whichever is less).  

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and 

associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes. NOTE: Follow all 

federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, 

state, or country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water 

intrusion). Fill in all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 

0.5 in. (13 mm), use an aluminum or zinc coated steel patch with rivets and sealant.

5.  Using the layout guidelines within the LED module installation instructions, determine required number of LED modules required to 

illuminate the sign.

6.  Using the applicable LED module maximum Loading chart, determine the number of Tetra Class 2 Power Supplies required to power 

the number of LED modules required to illuminate the sign, so as not to overload any single power supply output.

7.  Follow the LED module instructions to properly mount the LED modules. 

8.  Connect the DC output of the power supply to the LED modules using the Power Supply Installation instructions above.

9.  Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the Power 

Supply Installation instructions above.

10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country 

electrical codes.

1

Mount the power supply. Mounting 

the power supply base directly to 

a thermally conductive installation 

surface can improve thermal 

performance.
NOTE:

 All electrical connections 

should be suitably protected from 

mechanical damage and the 

environment. Seal all connections 

exposed to water with electrical 

grade self-hardening silicone.

 WARNING

RISK OF ELECTRIC SHOCK
AC input connections shall be 

suitably enclosed.

Summary of Contents for Tetra GEPS24-100U-GLX

Page 1: ...andard ICES 005 Ce DEFR de la classe A est conforme à la NMB 005 du Canada Prepare Electrical Wiring Electrical Requirements Limited to use in dry and damp locations The suitability of rain enclosure shall be determined if intended for wet location The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes ...

Page 2: ...deral and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Make sure the removal of lighting equipment does not compromise the...

Page 3: ...450 W1 GEPM2441 W1 GEPM2432 W1 0 84W module 96 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerMAX HO GEPMH2471 W1CS1 GEPMH2450 W1CS1 GEPMH2441 W1CS1 GEPMH2432 W1CS1 1 2W module 64 modules 64 ft 19 5 m 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m Tetra PowerStrip SS GESS2471 2 GESS2450 2 GESS2441 2 GESS2432 2 2 52W module 36 modules 20 ft 6 1 m 25 ft 7 6 m 35...

Page 4: ... 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF24DHOLED 1 GEF24SGNHOLED 1 GEF24CWHOLED 1 11 5W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF30DHOLED 1 GEF30SGNHOLED 1 GEF30CWHOLED 1 14 4W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF36DHOLED 1 GEF36SGNHOLED 1 GEF36CWHOLED 1 17 3W bar 16 ft 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GEF42DHOLED 1 GEF42SGNHO...

Page 5: ... 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06071A1 GETSPMDS06071B1 11 8 W Stick 7 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS06471A1 GETSPMDS06471B1 13 4 W Stick 6 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS07271A1 GETSPMDS07271B1 15 2 W Stick 5 Sticks 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m GETSPMDS08471A1 GETSPMDS08471B1 16 8 W Stick 5 Sticks 20 ft 6...

Page 6: ...nd power supply for improper termination s or short circuits Properly terminate or replace the wire connection s Check that connections are the red striped wire of the LED strip to the red wire of the power supply and the white wire of the LED strip to the black or blue wire of the power supply Chart continued Remote Mounting Distance Supports Tetra Products SKUs Rated Power Maximum Load per Power...

Reviews: