 CONNECTING THE DRYER TO HOUSE VENT

RIGID METAL TRANSITION DUCT

• For best drying performance, a rigid metal transition duct is 

recommended.

• Rigid metal transitions ducts reduce the risk of crushing and 

kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT

• If rigid metal duct cannot be used, then UL-listed flexible metal 

(semi-rigid) ducting can be used (Kit WX08X10077).

• Never install flexible metal duct in walls, ceilings, floors or 

other enclosed spaces.

• Total length of flexible metal duct should not exceed 8 feet 

(2.4m).

• For many applications, installing elbows at both the dryer and 

the wall is highly recommended (see illustrations). Elbows 

allow the appliance to sit close to the wall without kinking 

and or crushing the transition duct, maximizing drying 

performance.

• Avoid resting the duct on sharp objects.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

• In special installations, it may be necessary to connect the 

dryer to the house vent using a flexible metal (foil-type) duct. 

A UL-listed flexible metal (foil-type)duct may be used ONLY 

in installations where rigid metal or flexible metal (semi-rigid) 

ducting cannot be used AND where a 4” diameter can be 

maintained throughout the entire length of the transition 

duct.

• In Canada and the United States, only the flexible metal(foil-

type) ducts that comply with the “Outline for Clothes Dryer 

Transition Duct Subject 2158A” shall be used.

• Never install flexible metal duct in walls, ceilings, floors or 

other enclosed spaces.

• Total length of flexible metal duct should not exceed 8 feet 

(2.4m).

• Avoid resting the duct on sharp objects.

• For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.

2. Secure the duct with a clamp.

3. With the dryer in its permanent position, extend the duct to 

its full length. Allow 2” of duct to overlap the exhaust pipe. 

Cut off and remove excess duct. Keep the duct as straight 

as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the other clamp.

Summary of Contents for Spacemaker GTUP240EMWW

Page 1: ...visit www GEAppliances ca BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordina...

Page 2: ...from the power cord Follow national electrical codes and ordinances This appliance must be supplied with the voltage and frequency indicated on the rating plate located at the top of the dryer front...

Page 3: ...including handle and knobs NOTE With feet set at mid position feet can be adjusted 375 8 2 17 9 32 7 27 25 19 1 27 NOMINAL PRODUCT DIMENSIONS 75 5 52 9 Vent Water inlets rear Drain outlet rear 3 9 2 9...

Page 4: ...breakdown grounding will reduce the risk of electric shock by providing a path of least resistance of electric current This appliance is equipped with a cord having an equipment grounding conductor a...

Page 5: ...LY CORD KIT MARKED FOR USE WITH DRYERS PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS NOT SUPPLIED CONNECTING DRYER USING 3 WIRE CONNECTION 1 Turn off the circuit breaker s 30 amp or...

Page 6: ...through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up 3 EXHAUST INFORMATION WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EX HAUS...

Page 7: ...t will vibrate STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING WARNI...

Page 8: ...the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct...

Page 9: ...n inserting the duct 6 DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE APPLIANCE FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HAN...

Page 10: ...on SIPHON BREAK KIT For a drain facility less than 33 high the hose coupling and clamps provided in the machine must be used and in addition a siphon break MUST be installed on the back of the machine...

Page 11: ...liance back TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE FROM ACCUMULATING AND TO MAINTAIN DRYING EFFICIENCY THIS MACHINE MUST BE EXHAUSTED OUTDOORS Do not install this appliance with less than the m...

Page 12: ...NG INSTALLATION For replacement parts and other information refer to Owner s Manual for servicing phone numbers TO REGISTER YOUR DRYER CALL TOLL FREE 1 888 269 1192 In Canada call 888 561 3344 Prompt...

Page 13: ...s Plat Tourne vis A Douille Niveau 2 Rondellesen Caoutchouc Rondelles en caoutchouc les joints peuvent entre dans les tuyaux a eau 2 tuyaux de la laveuse 1 collier en plastique AVANT DE COMMENCER Lise...

Page 14: ...bois est suffisante Cet appareil ne devrait pas tre install sur untapis ou expos au climat PLOMBERIE PRESSION DE L EAU Elle doit tre de 20 psi minimum et 120 psi maximum TEMPERATURE DE L EAU le chauf...

Page 15: ...rm es incluant les poign es et les boutons NOTE Dimensions en pieds correspondant 375 8 2 17 9 32 7 27 25 19 1 DIMENSIONS NOMINALES DU PRODUIT DE 27 75 5 52 9 3 9 2 9 26 8 27 7 36 5 26 7 47 51 Dimensi...

Page 16: ...ence de normes locales conform ment AUX NORMES ELECTRIQUES NATIONALES ANSI NFPA NO 70 CONDITIONS ELECTRIQUES Cet appareil doit tre branch une prise lectrique individuelle prot g e par un fusible retar...

Page 17: ...S DE BASE AVEC DES EXTREMITES RETOURNEES PAS INCLUT BRANCHER L APPAREIL EN UTILISANT UNE CONNEXION TRIPHASEE 1 Eteignez le disjoncteur 30 amp ou d placez le fusible du circuit de la s cheuse au boitie...

Page 18: ...install es au moins 12 in Au dessus du niveau du sol ou cette distance au dessus de n importe quel autre objet pouvant faire obstruction cette sortie S PARATION DE TOURS Pour une meilleure performance...

Page 19: ...us du niveau du sol 5 METTRE A NIVEAU ET STABILISER VOTRE APPAREIL Mettre niveau et stabiliser votre appareil 1 D placez prudemment l appareil vers sa position finale Balancez avec douceur l appareil...

Page 20: ...er la s cheuse l a ration de la maison utilisant un tuyau flexible en m tal aluminium Un tuyau UL flexible en m tal semi rigide ne peut pas tre utilis ET ceci o un diam tre de 4 peut tre maintenu tout...

Page 21: ...T 1 Faites pivoter les sections du coude afin qu il soit dans la direction d sir e Pr parez l assemblagedu coude de 4 avec le tuyau de 4 Utilisez seulement le tuyau UL rigide en m tal approuv pour la...

Page 22: ...erieure 33 de hauteur le tuyau la connexion et les pinces fournies dans l appareil doivent tre utilis s et de plus un brise siphon DOIT tre install au dos de la machine Utilisez le Kit Brise SiphonWH4...

Page 23: ...NOMBRE DE PELUCHESET D HUMIDITE CAUSES PAR L ACCUMULATION ET POUR MAINTENIR L EFFICACITE DE SECHAGE CETTE MACHINE DOIT AVOIR UN SYSTEME D ECHAPPEMENT VERS L EXTERIEUR N installez pas cet appareil s il...

Page 24: ...APRES REPARATION ET D INSTALLATION Pour les pi ces de rechange et autres informations veuillez reporter au Manuel de l Utilisateur pour les num ros de t l phone du service apr s vente POUR ENREGISTRE...

Page 25: ...plana Llave para Turcas de 1 4 Nivel 2 Arandelas de Caucho 2 Pantallas de Filtro Arandelas de Caucho las arandelas podr n estar en mangueras de agua 2 Mangueras de Desag e para Lavadora 1 Enlace de Ca...

Page 26: ...cumpla con los est ndares de FHA Este electrodom stico no se deber instalar sobre tapetes ni estar expuesto la interperie PLOMER A PRESI N DEL AGUA Debe ser de un m nimo de 20 psi y un m ximo de 120...

Page 27: ...las perillas NOTA Con las patas en la posici n intermedia stas se pueden ajustar en 375 8 2 17 9 32 7 27 25 19 1 DIMENSIONES NOMINALES DEL PRODUCTO DE 27 75 5 52 9 Ventilaci n Entradas de agua trasera...

Page 28: ...e aparato est equipado con un cable que tiene un conductor de puesta a tierra y un enchufe de conexi n a tierra El enchufe debe conec tarse a un tomacorriente adecuado que est debida mente instalado y...

Page 29: ...SECADORAS Y PROVISTO CON TERMINALES DE BUCLE CERRADO O CON HORQUILLA CON EXTREMOS HACIA ARRIBA NO PROVISTO CONEXI N DE LA SECADORA USANDO UNA CONEXI N DE 3 CABLES 1 Apague el disyuntor es 30 amperios...

Page 30: ...e pared se deben instalar por lo menos a 12 sobre el nivel de suelo o en cualquier otra obstrucci n con la abertura en direcci n hacia abajo SEPARACI N DE CURVAS Para un mejor funcionamiento separe to...

Page 31: ...e external exhaust hood using duct tape or clamp CINTA DE CONDUCTO O ABRAZADERA DEL CONDUCTO ABERTURA DEL CONDUCTO EXTERNO CORTE DEL CONDUCTO DE METAL DE 4 PARA UNA LONGITUD APROPIADA CINTA DE CONDUCT...

Page 32: ...tipo hoja de aluminio Un conducto de metal flexible tipo hoja de aluminio podr ser usado S LO en instalaciones donde los conductos de metal r gido o metal flexible semi r gido no puedan ser usados Y d...

Page 33: ...ciones del codo de modo que apunten hacia el costado Realice un ensamble previo del codo de 4 con el conducto de 4 Use s lo metal r gido de 4 para conductos aprobados por UL dentro de la secadora Inse...

Page 34: ...nto con las abrazaderas provistas en la m quina deber n ser usadas y adem s se DEBER instalar una desviaci n del sif n en la parte trasera de la m quina Use el Kit de Desviaci n del Sif n WH49X228 y s...

Page 35: ...i n hacia el exterior Consulte la secci n de INFORMACI N DEL ESCAPE No instale este electrodom stico con menos del nivel de despeje m nimo como se muestra m s arriba El cl set debe contar con ventilac...

Page 36: ...OSO LUEGO DE LA INSTALACI N SERVICIO T CNICO Para el reemplazo de piezas y otras informaciones consulte los n meros telef nicos del servicio t cnico en el Manual del Propietario PARA REGISTRAR SU CENT...

Reviews: