3
Installation Instructions
STEP 3: Installation of the wall sleeve in
the wall opening
OPTION 1
1. Position the wall sleeve into the wall. Refer to chart on
SDJHIRUURRPVLGHSURMHFWLRQ7KHUHDURXWVLGHHGJH
RIWKHZDOOVOHHYHVKRXOGH[WHQGDWOHDVWó´EH\RQGWKH
RXWVLGHZDOOWREHDEOHWRFDXONSURSHUO\DQGSUHYHQWVHDOLQJ
WKHGUDLQKROHVLQWKHUHDUÀDQJHRIWKHZDOOVOHHYHDQGWR
IDFLOLWDWHHDV\LQVWDOODWLRQRIDQDFFHVVRU\GUDLQLIGHVLUHG
LILWLVGHVLUHGWRKDYHWKHUHDUJULOOHÀXVKRQWKHRXWVLGHD
GULSUDLOPXVWEHLQVWDOOHGXQGHUWKHZDOOVOHHYHDQGFDXONLQJ
DSSOLHGEHWZHHQWKHGULSUDLODQGZDOOVOHHYH
IMPORTANT:
Install wall sleeve level from side to side and with a slight
tilt from front to rear. Use a level; no more than a ¼ bub-
ble will be the correct wall sleeve slant to the outside.
Inside wall
)LUPO\VHFXUHWKHZDOOVOHHYHWRWKHZDOOVWUXFWXUHXVLQJWKH
H[LVWLQJKROHVRQWKHVLGHVDQGWRSRUE\GULOOLQJQHZKROHV
in the appropriate location.
Do NOT drill any holes in the
bottom of the wall sleeve.
8VHDSSURSULDWHVFUHZVODJ
EROWVHWFWRDWWDFKWKHZDOOVOHHYHWRWKHZDOOVWUXFWXUH
Secure case through
side and/or top only
2” min. from
case bottom
8VHDOLQWHOZKHQUHTXLUHGWRVXSSRUWEULFNDQGEORFNDERYH
the wall sleeve.
NOTE:
Do not drill any holes in the wall sleeve for electrical
connections.
STEP 3: Installation of the wall sleeve in
the wall opening (cont.)
OPTION 2
Installation of the wall sleeve into wall using
mounting brackets
8VH0RXQWLQJ%UDFNHWVSURYLGHGIRUSURSHUSRVLWLRQLQJRI
VOHHYHLQIUDPHGZDOORSHQLQJ6HH([SORGHG3DUWV3LFWXUH
3DJH6HOHFWHLWKHUIURQWRUUHDUVHWRIVOHHYHPRXQWLQJ
KROHVZKLFKZKHQDOLJQHGZLWKRQHRIWKHPRXQWLQJEUDFNHW
KROHVSURYLGHVWKHGHVLUHGSURMHFWLRQRIWKHVOHHYHLQWR
URRP5HPRYHSODVWLFKROHSOXJVIURPSODVWLFEDJRI
WKHLQFOXGHGSDUWV)DVWHQEUDFNHWVWRVOHHYHZLWKVFUHZV
IXUQLVKHGXVLQJVDPHKROHORFDWLRQLQHDFKPRXQWLQJ
EUDFNHW6LGHPRXQWLQJKROHVLQVOHHYHDUHRႇVHWIURPWRS
PRXQWLQJKROHVWRJLYHVOHHYHSURSHUUHDUZDUGVORSHWR
RXWVLGH,QVWDOOSODVWLFKROHSOXJVLQHPSW\KROHV
Alternate applications using wall sleeve mounting brackets
)UDPH&RQVWUXFWLRQDQG%ULFN9HQHHU
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
Solid Masonary Construction - Block
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
Solid Masonary Construction - Brick and Block
)UDPH2SHQLQJ0LQLPXP'LPHQVLRQV
ALTERNATE OPENING
2 x 4
FRAMING
25
15
ǫ
”
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
25
15
ǫ
”
36” MA
X.
ALTERNATE OPENING
2 x 4
FRAMING
25
15
ǫ
”
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
25
15
ǫ
”
36” MA
X.
LINTEL PURCHASED LOCALLY
SLEEVE
ELECTRICAL WALL
RECEPTACLE
36” MA
X.
ALTERNATE OPENING
2 x 4
FRAMING
25
15
ǫ
”
25
15
ǫ
”
Inside wall
Secure wall sleeve
WKURXJKVLGHDQGRU
top only
´PLQIURPZDOO
sleeve bottom