Installation Instructions (continue)

11. Fasten sub-base to wall using supplied #6 screws into wall 

anchors.

12. Refer to wiring diagrams and wire thermostat sub-base to the 

attached HVAC equipment.

13. To prevent electrical shorts and potential damage to the 

thermostat, ensure all of the sub-base wire  connections are 

secure and are not touching any other terminal. Push any 

excess wire back into wall cavity and insulate wire opening 

with suitable material.

14. On thermostat body, locate switch SW1 on thermostat circuit 

board.   

15. Set switch SW1-2 to HP for heat pump system or STD for 

conventional (or Standard) system. 
For heat pump system, set switch SW1-1 to E/B for heat 

changeover valve or G/O for cool changeover valve.  For 

conventional (or Standard) system, set switch SW1-1 to E/B for 

Electric or G/O for Gas.  

16. Attach front body of thermostat to sub-base of thermostat, 

being careful to align the terminal pins on the front body with 

the terminal block on the sub-base.

17. Restore system power and continue to Test the thermostat.

ON

1 2

ON

1 2

ON

1 2

ON

1 2

Electric 

Heat-Cool

Gas

 Heat-Cool

Heat

 Pump O

Heat

 Pump B

Summary of Contents for PROGRAMMABLE THERMOSTAT

Page 1: ...49 50274 03 11 GE PROGRAMMABLE THERMOSTAT Installation Instructions...

Page 2: ...ressive cleaning agents NOTICE This device shall only be used for its intended purpose as described in this Owner s Manual If this is a new installation locate the thermostat 4 to 5 feet above the flo...

Page 3: ...Heat 2 Stage Cool Heat Pump System 3 Refer to the wiring diagrams to determine the number of wires necessary to install this thermostat 4 Ensure the power to the air conditioning or heating system is...

Page 4: ...4 On thermostat body locate switch SW1 on thermostat circuit board 15 Set switch SW1 2 to HP for heat pump system or STD for conventional or Standard system For heat pump system set switch SW1 1 to E...

Page 5: ...n to highlight COOL Stage 1 Press the UP or DOWN button to toggle the COOL Stage 1 output ON OFF 5 Press the NEXT button to highlight COOL Stage 2 Press the UP or DOWN button to toggle the COOL Stage...

Page 6: ...s the UP or DOWN button to toggle the FAN output ON OFF After testing the FAN output keep it in the ON setting to test other outputs 5 Press the NEXT button to highlight COOL Stage 1 Press the UP or D...

Page 7: ...the NEXT button to highlight COOL Stage 1 Press the UP or DOWN button to toggle the COOL Stage 1 output ON OFF 6 Press the NEXT button to highlight COOL Stage 2 Press the UP or DOWN button to toggle t...

Page 8: ...ommon for control circuit and ther mostat power input G FAN Y 1st stage cooling 1st stage compressor Y2 2nd stage cooling 2nd stage compressor W 1st stage heating Auxiliary heating W2 E 2nd stage heat...

Page 9: ...Valve Aux Hea ng Emergency Emergency relay Auxiliary hea ng relay 1st Compressor Relay 2nd Compressor Relay Fan relay AC_ IN Power Supply AC_ IN MCU 1st Compressor 2nd Compressor Jumper Wire FAN FAULT...

Page 10: ...TING 1st HEATING 2nd HEATING Transformer 2nd hea ng relay 3rd hea ng relay 1st cooling relay Fan relay AC_ IN Power Supply AC_ IN 1st Cooling 2nd Cooling Jumper Wire FAN 24VAC Heat Cool 2nd cooling re...

Page 11: ...nearby the equipment strip 2 Label each wire to be connected eg RH RC C Y W G 3 The two leads of the Diobe Pair are connected to thermostat terminals Y to Y W to W Select one of the existing thermost...

Page 12: ...RH terminals The connection is shown below THERMOSTAT R C Y W D4 D3 Diode pair Jumper wire Add a wire for 4 wires system Jumper wire 1N4007T 1N4007T G RC STAT ACCESSORY EQUIP EQUIPMENT RH C RC RC C R...

Reviews: