PRODUCT DIMENSIONS
* For supplied duct cover ceiling height for vented installation and
recirculating installation, refer to the table on page 12.
3-1/8”
*Height to
ceiling
27-5/8”
35-7/8”
13-1/8”
INSTALLATION CLEARANCES
These vent hoods are
designed to be installed
onto a wall with no
above cabinets.
• Install these hoods
between the required
24” minimum and
36” recommended
maximum above the
cooking surface.
The vent hood must be
installed between the
required 24” minimum
and 36” recommended
maximum above the cooking surface. The hood
installation height above the cooking surface
depends upon ceiling height and duct cover
limitations. The telescopic duct cover conceals the
ductwork running from the top of the hood to the
ceiling.
NOTE:
Installation height should be measured from
the cooking surface to the lowest part of the hood.
This hood must be installed onto a wall. It can be
vented to the outdoors, or it can be installed for
recirculating operation. Recirculating Kit included
with hood.
2-3/8”
24” Required Min.
36” Recommended Max.
36” Typical
*Height to Ceiling
Vented
Recirculating
Min
34 5/8”
34 5/8”
Max
51 3/4”
57 1/4”
If you have questions, visit GEAppliances.com
, or call GE Appliances at 800.GE.CARES (800.432.2737).
Installation
Instructions
INST
ALLA
TION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
•
IMPORTANT
— Save these
instructions for local inspector’s use.
•
IMPORTANT
— Observe all
governing codes and ordinances.
•
Note to Installer – Be sure to leave these
instructions with the Consumer.
•
Note to Consumer – Keep these instructions
for future reference.
•
Skill level – Installation of this vent hood
requires basic mechanical and electrical skills.
•
Completion time – Approximately 4 to 6 hours
•
Proper installation is the responsibility of the
installer.
•
Product failure due to improper installation is
not covered under the Warranty.
FOR YOUR SAFETY
WARNING
Before beginning the
installation, switch power off at service panel
and lock the service disconnecting means
to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel.
CAUTION
Due to the weight and size
of these vent hoods and to reduce the risk
of personal injury or damage to the product,
TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.