49-2000833   Rev. 0

19

Installation Preparation

INSTALLATION PREPARATION: V

e

nted Outside

8  INSTALL VERTICAL SUPPORTS

• Install the 4 vertical supports wtih 16 - 4.2x8 mm 

screws. Make sure all screws are securely tightened.

A. 4 - Lower vertical supports

B. 16 - 4.2x8 mm screws

A

B

Summary of Contents for Profile PV977

Page 1: ...IPS 23 CONSUMER SUPPORT Warranty 27 Consumer Support 28 OWNER S MANUAL INSTALLATION INSTRUCTIONS PV977 Write the model and serial numbers here Model ___________________ Serial ___________________ You...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...O PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the...

Page 4: ...ith all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to...

Page 5: ...to your desired setting There are 4 fan levels LOW MED HIGH BOOST and OFF If you continue to press the or buttons the fan will cycle back through the settings NOTE There is an audible beep each time...

Page 6: ...her Charcoal Filter For recirculating installation only If the model is not vented to the outside the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors Th...

Page 7: ...Use a small flat blade screwdriver to remove the lamp lens cover Outer trim ring lamp assembly Do not remove Bulb Removable inner lamp lens cover NOTE Make sure the tabs are inserted into the slots T...

Page 8: ...ting Min 34 5 8 34 5 8 Max 51 3 4 57 1 4 If you have questions visit GEAppliances com or call GE Appliances at 800 GE CARES 800 432 2737 Installation Instructions INSTALLATION INSTRUCTIONS BEFORE YOU...

Page 9: ...duct cover ceiling heights for vented installation and recirculating installation refer to table on page 12 POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST...

Page 10: ...ze the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE When applicable in...

Page 11: ...Strain relief for junction box 8 Round metal duct length to suit installation Hammer Electric drill with 3 16 bits 2 Phillips head Flashlight UL listed wire nuts Pencil and tape measure REMOVE THE PAC...

Page 12: ...Wire Access Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Drill 3 16 Pilot Holes Approx 1 1 2 Deep 4 Places 8 1 4 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 10 5 16...

Page 13: ...to 36 30 to 36 10 4 36 31 to 36 10 5 32 to 36 10 6 33 to 36 10 7 34 to 36 10 8 35 to 36 10 9 36 based on 36 countertop height INSTALLATION CLEARANCES These vent hoods are designed to be installed onto...

Page 14: ...Cross framing wood supports Cooktop outline Align duct to center of cooktop Ceiling Support Structure At the hood location install cross framing between ceiling joists as shown 2x4 wood supports are...

Page 15: ...op outline Align duct to center of cooktop 16 Joist spacing 8 Duct Cooktop outline Align duct to center of cooktop EXAMPLE B EXAMPLE C Front of hood 10 5 16 Install cross framing symmetrically over du...

Page 16: ...user contact loads The hood support frame will be supported by the 2 x 4 cross framing Ductwork for Installations Vented to the Outdoors Use the shortest and straightest duct route for satisfactory p...

Page 17: ...ment with the countertop below Determine wire access hole location Center punch all screw and determined wire hole locations Drill pilot holes in the 4 screw locations Use a 3 16 bit and drill approxi...

Page 18: ...mm screws NOTE Attach the structure to the previously installed upper horizontal support A Upper horizontal support B 16 4 2x8 mm screws B A B INSTALLATION PREPARATION Vented Outside 6 INSTALL HOOD A...

Page 19: ...Preparation INSTALLATION PREPARATION Vented Outside 8 INSTALL VERTICAL SUPPORTS Install the 4 vertical supports wtih 16 4 2x8 mm screws Make sure all screws are securely tightened A 4 Lower vertical s...

Page 20: ...ill 3 16 Pilot Holes Approx 1 1 2 Deep 4 Places 8 1 4 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 31 14772 Printed in Mexico 12 08 JR 3 INSTA...

Page 21: ...er horizontal support with16 4 2 x 8 mm screws NOTE Attach the structure to the previously installed upper horizontal support A Upper horizontal support B 16 4 2x8 mm screws B A B 7 INSTALL HOOD ASSEM...

Page 22: ...Preparation INSTALLATION PREPARATION Recirculating 9 INSTALL VERTICAL SUPPORTS Install the 4 vertical supports wtih 16 4 2x8 mm screws Make sure all screws are securely tightened A 4 Lower vertical s...

Page 23: ...al airflow noise Obstructions in duct work Make sure nothing is blocking the vent Make sure your wall or roof cap has a blade or door Damper blade on wall or roof cap may not be open Make sure damper...

Page 24: ...t sensor detects the temperature has reached a safe condition A collar around a push button is not illuminating when pressed Push button may be stuck Check affected push button and ensure that it is n...

Page 25: ...49 2000833 Rev 0 25 Notes...

Page 26: ...49 2000833 Rev 0 26 Notes...

Page 27: ...ES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose...

Page 28: ...e while your warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com extended warranty or call...

Page 29: ...e marca MANUAL DEL PROPIETARIO Y INSTALACI N PV977 INFORMACI N DE SEGURIDAD 3 INSTRUCCIONES DE OPERACI N Controles de la luz 5 CUIDADO Y LIMPIEZA Filtro de grasa met lico 6 Filtro de carb n 6 Superfic...

Page 30: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Page 31: ...NCENDIO DE GRASA SOBRE UNA ESTUFA CUMPLA CON LOS SIGUIENTES PUNTOS A APAGUE LAS LLAMAS con una tapa que ajuste bien una plancha para galletas o una bandeja de metal y luego apague el quemador TENGA MU...

Page 32: ...B Es necesario contar con suficiente cantidad de aire para una combusti n y salida de gases adecuadas a trav s del conducto chimenea del equipo de consumo de combustible a fin de evitar r fagas de ai...

Page 33: ...nfiguraci n deseada Hay 4 niveles de ventilaci n LOW MED medio HIGH BOOST impulso y OFF Si contin a presionando los botones o el ventilador se desplazar a trav s de las configuraciones NOTA Puede o rs...

Page 34: ...car el filtro met lico ver la secci n Filtro de grasa met lico Filtros CUIDADO Y LIMPIEZA Filtros Mango con leng eta de bloqueo Mango con leng eta de bloqueo Filtro de grasa met lico El filtro met lic...

Page 35: ...nte en su lugar Utilice un destornillador plano para quitar la tapa de la bombilla Anillo exterior montaje de la bombilla No lo quite Bombilla Tapa de la bombilla interior desmontable NOTA Aseg rese d...

Page 36: ...n Recirculaci n M n 34 5 8 34 5 8 Max 51 3 4 57 1 4 ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores locales...

Page 37: ...onducto Para las alturas del cielorraso de las cubiertas del conducto provistas para instalaci n ventilada e instalaci n con recirculaci n consulte la tabla de la p gina 12 SUMINISTRO DE ENERG A IMPOR...

Page 38: ...Para minimizar las posibilidades de interrupci n de tales sistemas de ventilaci n natural siga las pautas y normas de seguridad del fabricante del equipamiento de calefacci n tales como las publicada...

Page 39: ...inta aislante de aluminio Gafas de seguridad Cable de 120V 60Hz 15 o 20 amperios de 2 hilos con circuito derivado con conexi n a tierra Escalera Sierra sable o serrucho de calar Destornillador de estr...

Page 40: ...para cables de de di metro seg n sea necesario Perfore orificios piloto de 3 16 de aprox 1 1 2 de profundidad en los 4 lugares indicados 8 1 4 hacia la l nea central de los orificios piloto 10 5 16 ha...

Page 41: ...irculaci n Se incluye un kit de recirculaci n con la campana 24 Requeridos M n 36 Recomendado Max 36 T pico Preparaci n para la instalaci n PV977 Cubierta de conducto superior 29 92 Cubierta de conduc...

Page 42: ...x 4 Contorno de la estufa Alinee el conducto con el centro de la estufa Estructura del soporte de cielorraso En la ubicaci n de la campana instale un armaz n cruzado entre las vigas como se indica Se...

Page 43: ...estufa Alinee el conducto con el centro de la estufa Espacio para viga de 16 Conducto de 8 Contorno de la estufa Alinee el conducto con el centro de la estufa EJEMPLO B EJEMPLO C 10 5 16 Instale el ar...

Page 44: ...a campana tendr el soporte de un armaz n cruzado de 2 x 4 Conductos para instalaciones con ventilaci n hacia el exterior Use el recorrido m s corto y directo para el conducto a fin de lograr un rendim...

Page 45: ...iloto perforados en el paso 1 Corte un orificio de acceso para cables de de di metro seg n sea necesario 8 1 4 hacia la l nea central de los orificios piloto 8 1 2 FRENTE DE LA CAMPANA Corte un orific...

Page 46: ...REALICE LA INSTALACI N EN EL SOPORTE SUPERIOR Instale la estructura en el soporte horizontal superior con los 16 tornillos de 4 2 x 8 NOTA Adhiera la estructura al soporte horizontal superior instala...

Page 47: ...res con los 2 tornillos niveladores y las 2 tuercas A 2 tornillos niveladores B Soporte vertical inferior C Coloque los tornillos niveladores a trav s de la estructura A B C 8 REALICE LA INSTALACI N D...

Page 48: ...del gancho hacia arriba Coloque el deflector de aire en el soporte del cielorraso con la abertura del conducto hacia arriba y uno de los lados abiertos hacia lo que ser el frente del montaje de la ca...

Page 49: ...16 tornillos de 4 2 x 8 NOTA Adhiera la estructura al soporte horizontal superior instalado A Soporte horizontal superior B 16 tornillos de 4 2 x 8 mm B A B 7 INSTALE EL ENSAMBLE DE LA CAMPANA EN EL S...

Page 50: ...CI N Recirculaci n 9 REALICE LA INSTALACI N DE LOS SOPORTES VERTICALES Instale los 4 soportes verticales con los 16 tornillos de 4 2 x 8 mm Aseg rese de que todos los tornillos est n ajustados de form...

Page 51: ...seg rese de que la tapa de pared o de techo cuenten con una paleta o puerta La paleta del regulador sobre la tapa de pared o de techo no se podr abrir Aseg rese de que el regulador se balancee libreme...

Page 52: ...e calor detecte que la temperatura alcanz una condici n segura Un aro alrededor de un bot n de presi n no se ilumina cuando es presionado Es posible que el bot n de presi n se encuentre atascado Contr...

Page 53: ...O VHUYLFLR WpFQLFR SDUD UHSDUDU R UHHPSOD DU ODV l mparas excepto las l mparas LED GARANT A LIMITADA Gracias por su compra de un electrodom stico de la Marca GE EXCLUSI N DE GARANT AS IMPL CITAS Su ni...

Page 54: ...ant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de GE Appliances a n estar n all cuando su garant a caduque En EE UU GEAppliances com extended warranty...

Reviews: