Heater
• The heating element is located above the drain at the bottom of the
outer tub.
• The Heating element is held in place by a compressed rubber gasket.
• When the 10-mm hex nut is tightened, it squeezes the rubber gasket
between the 2 mounting plates to seal the opening of the tub.
• The hex nut is set from the factory at 43.4 in. lbs of torque.