– 40 –
Test Mode
Test
Description
t4
Inlet Valve and Pressure
Sensor Check
Press start to initiate test. Each time start is pressed a
different valve is energized and a different corresponding
letter is displayed.
A : Cold valve is energized.
B : Hot valve is energized.
C : Jet spray valve is energized.
D : Bleach valve is energized.
E : Softener valve is energized.
Pump will activate when water frequency is 21.0 KHz.
Water level frequency will be displayed.
t5
Heater / Thermistor Test
Press start to initiate test. Tub will begin to
fi
ll with water.
When water reached the 25.8 KHZ level, heater will be
energized for 5 minutes. Water temperature will be
displayed. After 5 minutes, pump is energized.
t6
Pump Check
Press start to initiate test. Pump will be energized for 1
minute. After 1 minute, pump will turn off. Water frequency
will be displayed.
t7
Tidal Wave Wash Check
Press start to initiate test. Tub will spin CCW at @ 230 RPM
for 3 minutes. RPM value will be displayed.
t8
Agitate-1 Check
(Centrifusion Wash)
Press start to initiate test. Tub will slowly spin CW then
stop then spin for 3 minutes. With an empty tub, “720 ~
902 should be displayed. This is the reading from the load
sensor for an empty tub. It is not the RPM reading of the
tub speed.
t9
Agitate-2 Check (Infusor
Wash)
Press start to initiate test. Product will alternately rotate
infusor CW then CCW for 1 minute.
t10
Spin Check
Press start to initiate test. Pump will run until water
frequency is under 26.0 KHz. Tub will then slowly ramp up
to maximum RPM (1000 RPM), RPM will be displayed. Tub
will spin at maximum RPM for 3 minutes. After 3 minutes,
tub will slowly decelerate to 0 RPM. Note: 999 will be the
maximum RPM displayed.