– 30 –
The over
fl
ow sensor is located near the left side
of the drain pump and is inserted into a recess in
the washer
fl
oor. Two wires are connected to the
over
fl
ow sensor. It is necessary to remove the rear
cover to access the over
fl
ow sensor. (See
Top Cover
,
step 1.)
Overfl ow Sensor Removed
Thermistor/ATC Control (Auto Temp)
• The ATC control uses a water temperature
sensor (thermistor) to regulate the wash water
temperature.
• The thermistor has a negative temperature
coef
fi
cient (as temperature increases, resistance
decreases).
• The thermistor is located in the bottom of
the outer tub, under the wash basket. (See
Component Locator Views
.)
To determine the temperature of the incoming
water, the washer control measures the difference
between the voltage sent and the voltage returned
from the water temperature sensor. The washer
control then makes temperature adjustments
accordingly.
The washer control should maintain the water
temperature in the tub /- 5°F (+/- 3°C) by
opening or closing the hot and cold water valves.
The thermistor has an approximate resistance value
of 56K
at room temperature.
Water Temperature
Resistance ± 5%
86°F (30° C)
39.5 K
Ω
104°F (40° C)
26.1 K
Ω
140°F (60° C)
12.1 K
Ω
158°F (70° C)
8.5 K
Ω
203°F (95° C)
3.8 K
Ω
221°F (105° C)
2.8 K
Ω
The resistance of the thermistor can be checked
between the gray and white wires on the power
board white ATC connector. Make sure to unplug
the connector to isolate the thermistor before taking
resistance readings. (See
Circuit Board Connector
Locator View
.
)
(
Continued Next Page
)
MAIN P
CB ASSEMBL
Y
Summary of Contents for Profile PTWN8055MMS
Page 7: ...7...
Page 45: ...45 Wiring Diagram...