– 40 –
Control Board Testing
The resistance of various components can be checked from the Electronic Oven Control by the service
technician to quickly identify failed or improper operation of certain oven components.
For better clarity, some boards are shown with the top cover removed.
Note
: Colored dots on the relays match the color of the wire.
Hidden Bake Element
To test the hidden bake
element from the relay
board, disconnect the
orange wire at
DLB
. The
resistance should read
approximately 27
Ω
between
the orange wire at
DLB
and
the yellow wire at
BAKE
.
(See photo.)
Convection Element
To test the convection
element from the relay
board, disconnect the
orange wire at
DLB
.
The
resistance should read
approximately 22
Ω
between
the orange wire at
DLB
and
the blue wire at
CONV
.
(See
photo.)
Broil Element
To test the broil element
from the relay board,
disconnect the orange
wire at
DLB
. The resistance
should read approximately
24
Ω
between the orange
wire at
DLB
and the purple
wire at
BROIL
.
(See photo.)
Bake
DLB
Conv.
DLB
Broil
DLB