– 17 –
To replace the inner door assembly:
Remove the outer door assembly. (See
1.
Door
Assembly
.)
2. Remove the four T15 Torx screws (2 on each
side) that attach each door hinge to the inner
door. Carefully turn the door over and remove
both door hinges.
Remove the four 1/4-in. hex-head screws that
3.
attach the glass and side brackets (glass closest
to the outer door glass) to the inner door.
Remove the two T15 Torx screws (1 on each
4.
side) from the inner door assembly.
Caution:
Care must be taken if reinstalling the door
handle. Overtightening the screws can damage the
handle. Hand-tighten the screws and make sure
the handle
fi
ts snugly to the door panel. (Do not use
electric driver.)
(
Continued next page
)
To remove the outer door assembly:
Remove the door.
1.
Place the inner door assembly, gasket side up,
2.
on a protective surface.
Remove the four 1/4-in. hex-head screws from
3.
the bottom of the outer door assembly.
Note:
The inner door assembly is heavier than the
outer door assembly.
Separate the inner door assembly from the
5.
outer door assembly.
Remove the two 1/4-in. hex-head screws and
6.
brackets that hold the door handle to the outer
door assembly.
Door Shown with Inner Door Assembly Removed
Outer Door Assembly