– 56 –
CONTROL BOARD PIN DEFINITIONS
CONNECTOR
PIN
INPUT OUTPUT
FUNCTION
J7
1
VAC
Switched L1 voltage to the auger motor - 120 VAC.
J7
2
VAC
Switched L1 voltage to the cube solenoid - 120 VAC.
J7
3
VAC
Switched L1 voltage to the water valve - 120 VAC.
J7
4
VAC
Receives L1 input from freezer door switch when freezer door is
closed.
J7
5
VAC
Switched L1 voltage to the ExpressThaw (CustomCool™) heater
- 120 VAC.
J7
6
VAC
Receives L1 input from fresh food door switch when door is open.
This input is used for evaporator fan control, liner protection
mode calculations, door alarm calculations, and adaptive defrost
calculations.
J7
7
VAC
Receives L1 input from freezer door switch when door is open.
This input is used for evaporator fan control, liner protection mode
calculations, door alarm calculations, adaptive defrost calculations
and some door interlock functions. Switch must be closed in door
closed position (switch depressed) for dispenser LED light and duct
door magnet to energize.
J7
9
VAC
AC neutral in.
CONTROL BOARD PIN DEFINITIONS
CONNECTOR
PIN
INPUT OUTPUT
FUNCTION
J8
1
VAC
Switched L1 voltage to the compressor - 120 VAC. (Only used on
single-speed compressor models.)
(
Continued next page
)
CONTROL BOARD PIN DEFINITIONS
S
CONNECTOR PIN
INPUT OUTPUT
FUNCTION
J5
1
VDC
VDC
ExpressChill (CustomCool™) damper.
J5
2
VDC
VDC
ExpressChill (CustomCool™) damper.
J5
3
VDC
VDC
ExpressChill (CustomCool™) damper.
J5
4
VDC
VDC
ExpressChill (CustomCool™) damper.
J5
5
VDC
Provides 5 VDC for ExpressChill (CustomCool™) thermistor.
J5
6
VDC
Feedback of ExpressChill™ (CustomCool™) thermistor. Thermistor is
NTC (when temperature drops, resistance value increases), causing
return voltage reduction.