– 15 –
Freezer
Evaporator
Fresh Food
Evaporator
FREEZER SECTION COOLING
Condenser
Drier
Capillary
3-Way
Valve
Jumper
Tube
Accumulator
Muffler
Muffler
Compressor
Fresh Food Fan
Condenser Fan
Freezer Fan
Low Pressure Vapor
Mix of Liquid and Vapor
Low Pressure Liquid
High Pressure Liquid
Mix of Liquid and Vapor
High Pressure Vapor
Note:
The refrigerator will operate with the 3-way valve set for freezer only or set for fresh food and
freezer. There is no 3-way valve setting for fresh food only. If the fresh food thermistor is not satisfi ed,
but the freezer thermistor is satisfi ed, the refrigerator will still operate with the 3-way valve set in the
fresh food and freezer mode.