background image

4

ADJUST THE LOW FLAME (SIMMER)
SETTING

The top burner valves have low flame/simmer
adjustment screws in the center of the control shafts. 
A flashlight may be needed to locate the screw. A small,
thin-blade screwdriver (approximately 1/8

blade width)

is needed to access the screw.

Light two other burners and set the knobs to a
medium to high setting.

Light the burner to be adjusted and turn the knob

to LOW.

B

A

5

Conversion Instructions

Remove the knob and insert a screwdriver into 
the valve shaft.

Turn the adjustment screw until the flame reaches the
desired size.

Perform a flame stability test.

Flame Stability Test

Test 1: With the downdraft vent fan on HI, turn the 

burner knob from HI to LOW quickly. If the LOW
flame goes out, increase the flame size and test
again.

Test 2: With the burner on the LOW setting, open 

and close the cabinet door under the cooktop. If
the flame is extinguished by the air currents
created by the door movement, increase 
the flame height and test again.

Flame Recheck

After the adjustment is made, turn all burners off. Ignite
each burner individually. Observe the flame at the HI
position. Rotate the valve to the LOW position and be
sure the flame size decreases as the valve is rotated
counterclockwise.

E

D

C

CONVERTING BACK TO NATURAL GAS

Reverse the procedures for converting to LP, locating 
the orifices as follows:

N

N

150

150

N

N

122

169

Front

Natural Gas 4

W.C.P.

Burner Output Rating in BTU/HR

Location

BTUs

Orifice Size

LF, LR

9,100

1.50 Nmm

RR

5,500

1.22 Nmm

RF

11,500

1.69 Nmm

Use for cooktop operation at elevations above 5000 ft. (1500m). 
Specify kit for Natural Gas or LP Gas when ordering:
Natural Gas High Altitude Orifice Conversion Kit.........WB28X10114 
LP High Altitude Orifice Conversion Kit..................................WB28X10115

High Altitude Orifice Conversion Kit

Summary of Contents for PGP989

Page 1: ...be made before attempting burner adjustments or use of the cooktop WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and...

Page 2: ...ing any pressure testing of that system at test pressures greater than 1 2 psig Isolate the cooktop from the gas supply piping system by closing the individual manual shut off valve to the cooktop dur...

Page 3: ...OFF and turn the gas supply valve to ON 3 Apply the liquid leak detector or the soap solution around all connections from the shut off valve to the cooktop 4 A leak is identified by a flow of bubbles...

Page 4: ...2 With the burner on the LOW setting open and close the cabinet door under the cooktop If the flame is extinguished by the air currents created by the door movement increase the flame height and test...

Page 5: ...de intentar modificaciones en los quemadores o de utilizar la estufa ADVERTENCIA Este kit de conversi n debe ser instalado por una agencia de servicios calificada de acuerdo con las instrucciones del...

Page 6: ...SCONECTE EL SUMINISTRO DE ELECTRICIDAD DESDE LA ESTUFA DESCONECTE EL SUMINISTRO DE GAS Y DE ELECTRICIDAD L L 84 84 L L 71 99 CONVERSI N DE QUEMADORES DE SUPERFICIE Primero quite convierta y reemplace...

Page 7: ...a posici n encendido ON 3 Aplique el detector l quido de p rdidas o la soluci n jabonosa alrededor de todas las conexiones desde la v lvula de apagado hasta la estufa 4 Se produce un flujo de burbujas...

Page 8: ...configuraci n LOW baja abra y cierre la puerta del gabinete ubicada debajo de la estufa Si la llama se apaga por la corriente de aire creada por el movimiento de la puerta aumente la altura de la llam...

Reviews: