background image

CONVERT SURFACE BURNERS (cont.)

Replace the gaskets, burner bases and electrodes.
Install the two screws in each burner base. Do not
overtighten. The maximum torque is 10 inch pounds.
Push the igniters all the way down into the burner
head.

Install the burner heads, burner caps and grates in
their original burner positions.

E

D

1

Conversion Instructions

CONVERT THE PRESSURE REGULATOR

Locate the pressure regulator under the rear 
of the cooktop.

A

2

Remove the nut from the pressure regulator with 
an adjustable wrench.

B

Remove the plastic pin from the inside of the nut, 
turn the pin 180° and snap the pin back into the nut.

C

Natural gas

LP gas

Nut

Natural gas

LP gas

Nut

TEST FOR LEAKS

WARNING:

DO NOT USE A FLAME TO CHECK

FOR GAS LEAKS! 

Do not use the cooktop until all

connections have been leak tested.

Perform leak test per the following instructions:

1.

Purchase a liquid leak detector or prepare a soap
solution of one part water, one part liquid detergent.

2.

When all connections have been made, make sure all
cooktop controls are turned to 

OFF

and turn the gas

supply valve to 

ON

.

3.

Apply the liquid leak detector or the soap solution
around all connections from the shut-off valve 
to the cooktop.

4.

A leak is identified by a flow of bubbles from the 
area of the leak.

5.

If a leak is detected, turn the gas supply 

off

. Tighten

the fitting. Turn the gas on and test again.
If the leak persists, turn the gas supply 

off 

and

contact your dealer for assistance. Do not attempt 
to operate the cooktop if a leak is present.

3

3

Pressure 
regulator

Re-install the nut onto the regulator.

Apply the LP Conversion label next to the Rating Plate.

E

D

CHECK IGNITION

Connect electrical supply cord.

Push in one control knob and turn to the 

LITE

position. The igniter will spark and the burner will
light. The first test may require some time, while air
is flushed out of the gas line.

B

A

4

Check to determine if your burner flames are normal.
If burner flames look like A, call for service. Normal
burner flames should look like B or C, depending on
the type of gas you use. With LP gas, some yellow
tipping on outer cones is normal.

C

Turn the knob to 

OFF

.

Repeat the procedure for each burner.

E

D

A–Yellow flames

Call for service

B–Yellow tips

Normal for 
LP gas

C–Soft blue flames

Normal for 
natural gas

Summary of Contents for PGP989

Page 1: ...be made before attempting burner adjustments or use of the cooktop WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and...

Page 2: ...ing any pressure testing of that system at test pressures greater than 1 2 psig Isolate the cooktop from the gas supply piping system by closing the individual manual shut off valve to the cooktop dur...

Page 3: ...OFF and turn the gas supply valve to ON 3 Apply the liquid leak detector or the soap solution around all connections from the shut off valve to the cooktop 4 A leak is identified by a flow of bubbles...

Page 4: ...2 With the burner on the LOW setting open and close the cabinet door under the cooktop If the flame is extinguished by the air currents created by the door movement increase the flame height and test...

Page 5: ...de intentar modificaciones en los quemadores o de utilizar la estufa ADVERTENCIA Este kit de conversi n debe ser instalado por una agencia de servicios calificada de acuerdo con las instrucciones del...

Page 6: ...SCONECTE EL SUMINISTRO DE ELECTRICIDAD DESDE LA ESTUFA DESCONECTE EL SUMINISTRO DE GAS Y DE ELECTRICIDAD L L 84 84 L L 71 99 CONVERSI N DE QUEMADORES DE SUPERFICIE Primero quite convierta y reemplace...

Page 7: ...a posici n encendido ON 3 Aplique el detector l quido de p rdidas o la soluci n jabonosa alrededor de todas las conexiones desde la v lvula de apagado hasta la estufa 4 Se produce un flujo de burbujas...

Page 8: ...configuraci n LOW baja abra y cierre la puerta del gabinete ubicada debajo de la estufa Si la llama se apaga por la corriente de aire creada por el movimiento de la puerta aumente la altura de la llam...