![GE PFWS4400L0 Technical Service Manual Download Page 46](http://html.mh-extra.com/html/ge/pfws4400l0/pfws4400l0_technical-service-manual_134025046.webp)
– 46 –
Belt
To remove the belt:
1. Remove the four 6-mm screws from the
cabinet's rear cover.
Note:
The belt is elastic and designed to be removed
and installed in this manner.
Belt
Tub Drive
Pulley
2. Pull the cover outward from the middle.
3. Remove the belt by turning the tub drive pulley
and rolling the belt off the pulley.
Caution:
When installing, use a torque wrench to
tighten the 18-mm hex nut to 44 ft. lbs of torque.
Drive Nut
(Continued Next Page)
Wash Basket Pulley
To remove the wash basket pulley:
1. Remove the belt. (See
Belt
.)
2. Remove the 18-mm hex nut that holds the tub
drive pulley to the wash basket. Remove the
pulley.