![GE PFWS4400L0 Technical Service Manual Download Page 40](http://html.mh-extra.com/html/ge/pfws4400l0/pfws4400l0_technical-service-manual_134025040.webp)
– 40 –
8. Remove the 4 Phillips-head screws from the
overnight ready fan motor and remove the
motor from the fan housing.
Steam Generator
The steam generator is rated at 1000 watts, 120
VAC, 8.3 amps, and 15
It consists of a water tank,
an electric heater, and 2 thermostats. The safety
limit opens at 403°F, and the cycling thermostat
opens at 266°F and resets at 221°F.
To remove the steam generator:
1. Remove the top panel. (See
Top Panel
.)
2. Remove the 4 Phillips-head screws holding the
steam generator to the rear panel and cross
support.
3. Disconnect the 4 wiring harnesses and wire tie
from the steam generator.
Disconnect
Disconnect
4. Remove the 2 hoses from the steam generator.
Note:
The steam hoses are dif
fi
cult to remove.
a. Squeeze each clamp and slide it back.
b. Carefully break each hose loose by inserting
a small,
fl
at blade screwdriver under the
hose to break the seal.
c. Remove the hoses.
Summary of Contents for PFWS4400L0
Page 9: ... 9 Continued Next Page ...
Page 11: ... 11 Continued Next Page ...
Page 13: ... 13 Continued Next Page ...
Page 14: ... 14 Continued Next Page ...
Page 19: ... 19 ...
Page 22: ... 22 Dispenser Drawer Tub Drive Pulley Belt Motor Rear View Front View Con t ...
Page 65: ... 65 Schematics Model 4600 with Steam ...
Page 66: ... 66 Model 4400 without Steam ...