– 38 –
Operation of the water level control can be checked
by using service test mode t09. (See
Service Test
Mode
.)
Speci
fi
c failures associated with the water level
control can initiate error codes E6 and E14. (See
Error Codes
.)
6. Remove the pressure tube.
Note:
The pressure tube is dif
fi
cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small,
fl
at blade screwdriver under the hose
to break the seal.
c. Remove the hose.
Pressure Tube
Clamp
Disconnect
Disconnect
To remove the water level control:
1. Remove the top panel. (See
Top Panel
.)
2. Remove 4 Phillips-head screws from the cross
support and 4 Phillips-head screws from the
steam generator.
3. Remove the two 6-mm hex-head screws holding
the overnight ready fan bracket to the overnight
ready fan housing.
Note:
The fan bracket is attached to the washer
frame with 1 screw and a tab.
5. Disconnect the 2 wire harnesses.
Overfl ow Water Level
The over
fl
ow water level is approximately 7 inches
above the door opening. Over
fl
ow protection will
occur when this water level is reached.
4. Remove the 6-mm hex-head screw from the
overnight ready fan bracket and remove the
bracket by sliding it up and out to release the
tab.
7. Rotate the water level control 1/4-turn clockwise
and pull it out of the cabinet.
Summary of Contents for PFWS4400L0
Page 9: ... 9 Continued Next Page ...
Page 11: ... 11 Continued Next Page ...
Page 13: ... 13 Continued Next Page ...
Page 14: ... 14 Continued Next Page ...
Page 19: ... 19 ...
Page 22: ... 22 Dispenser Drawer Tub Drive Pulley Belt Motor Rear View Front View Con t ...
Page 65: ... 65 Schematics Model 4600 with Steam ...
Page 66: ... 66 Model 4400 without Steam ...