GE Energy Motors GEEP-427-I Copyright 2009, The General Electric Company, USA
34
GEEP-427-I Pegasus, Horizontal Induction Motor
TEWAC, Sleeve Bearing
Trouble Possible
Cause
Action
Low insulation resistance
or insulation failure
Mechanical damage to insulation.
Obtain expert help for repair.
(cont’d)
Voltage surges have damaged
insulation.
Obtain expert help for repair
Excessive temperatures
Obtain expert help for repair
BOLT TIGHTENING REFERENCE
Bolt size
Torque in LB. FT
Dry
Lubricated
1/4 - 20
8
7
5/16 - 18
17
14
3/8 - 16
30
23
7/16 - 14
50
38
1/2 - 13
75
56
5/8 - 11
150
112
3/4 - 10
260
188
7/8 - 9
400
284
1 - 8
580
438
1 1/4 - 7
1120
823
1 1/2 - 6
1940
1311
Summary of Contents for Pegasus MHV GEEP-427-I