Freeze Sentinel

All Zoneline units are equipped with Freeze Sentinel to 
provide protection against damage caused by freezing 
temperatures in unoccupied rooms, regardless of unit 
setting. In installations where freezing temperature is  
not a concern, the owner has the option of disabling  
the Freeze Sentinel.

The Dry Air 5

The Dry Air 5 Series centers around GE’s exclusive use of 
the patented Dinh

®

 Dehumidifier Heat Pipe from Heat Pipe 

Technology, Inc. This innovative technology enables the  
Dry Air 5 to remove 5% more moisture from the air than 
standard GE packaged terminal air conditioners. The Dry Air 
5 is perfect for high-humidity climates. Available on 7000, 
9000 and 1000 BTU models.

Upfront filters

For ease of cleaning, all Zoneline units have interchangeable, 
removable upfront filters made of long-lasting nylon mesh, 
thus assuring high performance and long life.

Electronic temperature limiting

Heating and cooling temperatures may be electronically 
limited on all series to prevent expensive overcooling or 
overheating. Heating and cooling limits are independently 
set so seasonal adjustment is unnecessary.

Heat Sentinel

Provides automatic protection against overheating by 
switching on the unit to cool should the temperature  
of an unoccupied room reach 85°F.

Summary of Contents for PDW9880J

Page 1: ...GE Zoneline packaged terminal air conditioners...

Page 2: ......

Page 3: ...d apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable ro...

Page 4: ...ts are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units...

Page 5: ...m the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all...

Page 6: ...f cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resis...

Page 7: ...control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Au...

Page 8: ...ating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electrom...

Page 9: ...perature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides au...

Page 10: ...ty RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected u...

Page 11: ...0 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265...

Page 12: ...olenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in mater...

Reviews: