Grille options

Extruded aluminum:

RAG7 (Shown)

Stamped aluminum grille

RAG0

Exterior architectural louvers

Durable polycarbonate:

RAG1 (Warm Grey Beige)

RAG (Maple)

RAG (Bittersweet Chocolate)

Retrofit kits

 (not shown)

RAK901L

 - Wall Case Insulation for use  

with Heat Pumps

RAK40

 - Deflector Kit to adapt chassis for  

use with existing exterior architectural  

louvered grilles

Requires power connection kit  

Resistance heat

Heat pump

Deluxe 

2900 Series

Deluxe 

Dry Air 25

Deluxe 

3900 Series

Premium  

5800 Series

Features

Highly featured  
microcomputer controls

 

Standard

 

Standard

 

Standard

 

Standard

Tactile touch pad controls with LED

Standard

Standard

Standard

Standard

Universal heaters

Standard

Standard

Standard

Standard

Solid-state thermostat

Standard

Standard

Standard

Standard

-position vent control

Standard

Standard

Standard

Standard

Upfront filter (interchangeable)

Standard

Standard

Standard

Standard

Automatic indoor frost control

Standard

Standard

Standard

Standard

Sleep function

Standard

Standard

Standard

Standard

Corrosion-treated chassis

Optional

Standard

Optional

Standard

-position discharge grille

Standard

Standard

Standard

Standard

Fan motors

“SmartFan” Fan cycle control

Standard

Standard

Standard

Standard

Fan Only setting—-speed

Hi/Low

Hi/Low

Hi/Low

Hi/Low

Indoor fan speed

Hi/Low

Hi/Low

Hi/Low

Hi/Low

Cool & heat only settings

Hi/Low/Auto

Hi/Low/Auto

Hi/Low/Auto

Hi/Low/Auto

Staged heating

-stage

-stage

Freeze Sentinel™

Standard

Standard

Standard

Standard

Heat Sentinel

Standard

Standard

Standard

Standard

Temperature limiting

Electronic 7-step Electronic 7-step Electronic 7-step Electronic 7-step

Remote control compatibility

Standard

Standard

Standard

Standard

Central desk control compatibility

Standard

Standard

Standard

Standard

Service indicator

Standard

Heat pump with resistance  
heat back-up

 

 

 

Standard

 

Standard

Heat pump with supplemental  
resistance heat

 

 

 

Standard

 

Standard

Automatic emergency heat

Standard

Standard

Standard

Standard

Electric resistance heat lock-out

Standard

Standard

Heat pump defrost system

Reverse cycle

Reverse cycle

Internal condensate removal (ICR)*

Optional

Optional

Quick heat recovery

Standard

Standard

Self-diagnostics

Standard

Auto power recovery

Standard

Standard

Standard

Standard

*Not for use in corrosive environments

Chassis

Grille

Premium 5800 series 
cooling with heat pump  
and resistance heat

Includes all features of 900 series, plus:
•  Two-fan-motor system with indoor  

cross flow blower

  - For quieter operation
• Corrosion treatment is standard
• Self-diagnostics
•  Connections for infrared/door  

switch sensors

Summary of Contents for PDW9880J

Page 1: ...GE Zoneline packaged terminal air conditioners...

Page 2: ......

Page 3: ...d apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable ro...

Page 4: ...ts are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units...

Page 5: ...m the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all...

Page 6: ...f cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resis...

Page 7: ...control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Au...

Page 8: ...ating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electrom...

Page 9: ...perature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides au...

Page 10: ...ty RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected u...

Page 11: ...0 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265...

Page 12: ...olenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in mater...