background image

Zoneline

®

 chassis nomenclature

For GE appliance service in the US, call  
1-800-GE CARES. In Canada call 1-888-09-0999.

GE has a policy of continuous improvement of  
its products and reserves the right to change  
materials and specifications without notice.

© 008 GE Company

Pub. No. 0-S097          PC5190

Listed by

Underwriters

Laboratories.

M

A

N

U

F

A

C

TU

RE

R

CE

RTI

FIED TO ARI AS

CO

M

PL

Y

IN

G

W

IT

H

AR

I STANDARD 3

10

P

A

C

K

AG

ED

TE

RM

IN

A

L

AIR

-CONDITIONER

S

R

M

A

N

U

F

A

C

TU

RE

R

CE

RTI

FIED TO ARI AS

CO

M

PL

Y

IN

G

W

IT

H

AR

I STANDARD 3

80

P

A

C

K

AG

ED

TE

RM

IN

A

L

HEAT PUMPS

R

Zoneline warranty*

What is covered

Limited one-year warranty

For one year from the date of the original purchase, GE will repair or 
replace any part of the air conditioner which fails due to a defect in 
materials or workmanship. During this limited one-year warranty, GE 
will provide, free of charge, all labor and related service costs to repair 
or replace the defective part.

Limited five-year warranty

For five years from the date of the original purchase, GE will repair 
or replace the Sealed Refrigerating System if any part of the Sealed 
Refrigerating System (the compressor, condenser, evaporator, and 
all connecting tubing) should fail due to a defect in materials or 
workmanship. During this limited five-year warranty, GE will provide, free 
of charge, all labor and related service costs to repair or replace  
the defective part.

Limited second through fifth year parts warranty

From the second through the fifth year from the date of the original 
purchase, GE will replace the Fan Motors, Switches, Thermostat, Heater, 
Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, 
Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump, 
Capacitors, Varistors and Indoor Blower Bearing, if any of these parts 
should fail due to a defect in materials or workmanship. During this  
additional four-year limited warranty, you will be responsible for any 
labor and related service costs.

*See written warranty for details

The Zoneline

®

 chassis is identified by a model number defining the type 

of unit, cooling capacity, electrical information and optional features 
included on the unit. When specifying or ordering the Zoneline chassis, 
use of this nomenclature will assure receiving the correct unit.

For detailed information on operating specifications, installation data and accessories, 
see the GE Zoneline Architects and Engineers Design Data Manual.

A

Z

5

8

H

1

2

D

A

D

Chassis series

9= deluxe line cool/

electric heat

9=deluxe line heat pump

58= premium line  

heat pump

Unit type

E= cooling with electric 

resistance heat

H= heat pump with electric 

resistance heat

Zoneline

packaged 

terminal 

chassis

Nominal cooling capacity

07=7,000 BTUH cooling 

09=9,000 BTUH cooling 

1=1,000 BTUH cooling 

15=15,000 BTUH cooling

Special Features

B=base unit

C=corrosion treated

D= internal 

condensate 

removal (ICR)  

system (heat 

pump models 

only) (not for 

coastal areas)

P=Dry Air 5

Voltage/Phase/

Frequency

D= 0/08 Volt, single 

phase, 0 Hz

E= 5 Volt, single phase, 

0 Hz

Universal  

power connection

GE Consumer & Industrial

Appliances

General Electric Company

Louisville, KY 40225
ge.com

zoneline.com

A century of quality and innovation

For more than a century, GE has been committed to producing innovative products  
that change the way people live. The result of thorough research and rigorous testing,  
GE appliances are designed for years of dependable performance.  
Today, the GE tradition of quality and innovation continues.

Summary of Contents for PDW9880J

Page 1: ...GE Zoneline packaged terminal air conditioners...

Page 2: ......

Page 3: ...d apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable ro...

Page 4: ...ts are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units...

Page 5: ...m the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all...

Page 6: ...f cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resis...

Page 7: ...control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Au...

Page 8: ...ating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electrom...

Page 9: ...perature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides au...

Page 10: ...ty RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected u...

Page 11: ...0 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265...

Page 12: ...olenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in mater...