background image

5.4

USB Ports

For maximum cable length,
refer to the table

Summary of

Cabled Ports

.

Two ports are provided for connection of USB 2.0 compatible devices, such as a
keyboard, mouse, serial communications or data storage device.

Attention

Double-shielded cable that complies with USB 2.0 is
required.

Note

These USB ports are defined as maintenance ports and are intended to be used only

as temporary connections.

Pin #

Signal

Pin 1

4

GND

3

+ Data

2

- Data

1

Current limited 5 V dc

36

GFK-2898B

PACSystems 19" RXi Display

For public disclosure

Summary of Contents for PACSystems

Page 1: ...GFK 2898B PACSystems 19 RXi Display User Manual Jan 2016 For public disclosure ...

Page 2: ... included therein as is and without warranty of any kind expressed or implied including but not limited to any implied statutory warranty of merchantability or fitness for particular purpose For further assistance or technical information contact the nearest GE Sales or Service Office or an authorized GE Sales Representative Revised Jan 2016 Issued Apr 2014 Copyright 2014 2016 General Electric Com...

Page 3: ...Protocol FG Frame Ground GND Ground HDD Hard Disk Drive IPC Industrial PC mPCIe Miniature PCI Express RAM Random Access Memory RTC Real Time Clock SATA Serial ATA SD Secure Digital SELV Safety Extra Low Voltage SSD Solid State Drive SVGA Super Video Graphics Array USB Universal Serial Bus VGA Video Graphics Array WWAN Wireless Wide Area Network GFK 2898B 3 For public disclosure ...

Page 4: ...result in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Attention Indicates a procedure condition or statement that should be strictly followed to improve these applications For public disclosure ...

Page 5: ...hnical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support http support ge ip com Phone 800 1 433 2682 EMEA Direct Dial 420 23 901 5850 if toll free 800 option is unavailable or dialing from a mobile telephone Technical Support Email support emea ip ge com Customer Care Email custo...

Page 6: ...Notes 6 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 7: ...Down the Computer 23 2 4 1 Disabling Operating System Shutdown 24 3 Hardware Installation 25 3 1 Mounting and Installation Guidelines 25 3 2 Grounding 25 3 3 Mounting and Installation 26 3 3 1 Removal 27 4 Service and Maintenance 29 4 1 Real Time Clock Battery Replacement 29 4 2 Disabling the Off Button 32 5 Connectors and Cabling 33 5 1 Input Power 33 5 2 Ethernet Communication Ports 34 5 2 1 Eth...

Page 8: ...Government Regulations 43 Index 45 8 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 9: ...corporates RXi Box IPC processor hardware to create a system that lowers total cost ownership with seamless replacement of either the processor or display component and provides for powerful upgrades to the underlying computing technology The RXi Display can be mounted directly into an industrial panel The RXi Display is a 1 GHz x86 64 based fanless computing platform with a 19 display and a high ...

Page 10: ...19 RXi Display Front View 19 RXi Display Rear View 10 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 11: ...clock RTC accuracy Maximum drift of 2 seconds day at 25 C 77 F Video Standard 15 pin VGA connector Maintenance ports Intended only for temporary connection Two Type A USB 2 0 SD standard card slot Dual function Audio OUT Microphone IN jack 3 5 mm four pin TRRS Power requirements 2 6 A at 24 V dc 18 to 32 V dc LPS or Class 2 power supply required Serial Communications One RS 232 RJ 45 port Ethernet...

Page 12: ...ive Strength 400 MPa Electrical Grounding Frame ground FG internally connected to signal ground Physical Material Aluminum bezel Enclosure Rating UL NEMA Type 1 Depth to Panel 10 16 mm 0 4 in Panel Cutout Dimensions 457 x 292 mm 18 x 11 5 in Panel Thickness 1 5875 to 4 7625 mm 0 0625 to 0 1875 in Minimum Clearances around RTM Each side 51 mm 2 in Top and bottom 127 mm 5 in Feature LED Indicators W...

Page 13: ...temporarily become conductive due to occasional condensation 1 Applies only to 19 Displays with solid state hard drive 2 For ambient temperatures greater than 50 C 122 F the unit must be installed in a restricted access area as defined in this document Warning If the RXi Display is operating in ambient temperatures greater than 50 C 122 F its exterior temperatures may be too hot to touch safely To...

Page 14: ...e format TFT LCD display Power on off and three user defined capacitive touch buttons with LED indicators Status indicators for disk activity and over temperature Status indicators for Wi Fi Bluetooth and WWAN connectivity from optional mPCIe card SD card slot Note Status indicators are hidden on the display until they show activity Note When the SD card is not installed a rubber cover is provided...

Page 15: ...d Menu Plus Minus Power On Off Overtemp SATA Drive Activity Bluetooth Wi Fi WWAN Input Power Ethernet 1 Ethernet 2 VGA USB 1 USB 2 Serial RS 232 Connector Panel RXi Display Features Overview GFK 2898B 15 For public disclosure ...

Page 16: ... remains green while the unit is shutting down and displays as white when the unit is powered down Force shutdown Touch the button for at least 4 seconds The LED turns white when the unit is powered down Caution Use this option only if the operating system is non responsive The LED displays solid red to indicate a fault including over temperature condition User defined Button and LED Operation But...

Page 17: ...ite solid Connected to WWAN optional mPCIe card 1 2 3 Ethernet Port LEDs Each Ethernet port has two LED indicators ACTIVITY and LINK LED Status Indicator State Description Activity Activity LED Link LED Green blinking Traffic is detected at the port Link Green on solid Link is operational 1 2 4 SD Card Slot The display accommodates a user supplied SD card for auxiliary storage The front mounted SD...

Page 18: ...Notes 18 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 19: ...h you should action be necessary After unpacking the RXi Display record all serial numbers Serial numbers are required if you need to contact Customer Care during the warranty period All shipping containers and packing material should be saved should it be necessary to transport or ship any part of the system For phone numbers and email addresses refer to the section Contact Information Verify tha...

Page 20: ... the building installation wiring Note The product is supplied with a Phoenix Contact part number 1827716 power terminal block plug Phoenix Contact part number 1851245 spring loaded quick release power terminal block plug may also be used Power cord with 24 16 AWG wires user calculates proper wire gauge according to local regulations One small blade flat head screwdriver for M2 and M2 5 machine sc...

Page 21: ...ional use During power up you should see the normal operating system starting displays on the monitor During normal power up and operation the Power On Off status indicator displays as follows Power On Off LED Status Indicator LED Description Solid white RXi Display is off Blinking blue RXi Display is turned on after input power is restored Solid green RXi Display has completed startup and is runn...

Page 22: ...Connectors and Cabling 2 When prompted by the operating system restart the RXi Display 3 Connect the RXi Display to the Ethernet network 2 3 1 Pinging TCP IP Ethernet Interfaces on the Network Most nodes on TCP IP networks including the PACSystems Ethernet interface implement a PING command Ping each installed Ethernet device When the Ethernet device responds to the ping it verifies that the devic...

Page 23: ... RXi Display Refer to the table Power On Off LED Status Indicator 1 Touch Power On Off briefly between 100 ms and 4 seconds or select Shut Down from the Windows Start menu This provides a controlled shutdown of the operating system before removing power from the system The status indicator remains solid green while the RXi Display is shutting down and then turns white when the RXi Display has fini...

Page 24: ...me to 4 seconds using Windows 7 settings To change the Off button touch time using Windows 1 From the Start menu select Control Panel 2 Select Hardware and Sound section if displayed 3 Select Power Options 4 Select Choose what the power buttons do 5 Change the When I press the power button selection to Do Nothing 6 Save the changes Note To completely disable the power off function set a switch tha...

Page 25: ...pation To avoid impacting mechanical reliability and signal quality cable installation must comply with the minimum bend radius specified by the cable manufacturer 3 2 Grounding The following guidelines apply for proper grounding Note These grounding connections serve as a path for reducing noise interference and radiated emissions and are required for the RXi Display to comply with the standards ...

Page 26: ... replace if necessary 2 Swing the eight levers on the back of the RXi Display to their retracted position held in place by a ball plunger 3 From the front of the enclosure tilt the RXi Display into the enclosure opening and rest its two lower brackets on the enclosure opening bottom edge 4 Push the top of the RXi Display towards the enclosure until the top latch catches the enclosure opening top e...

Page 27: ...heir retracted position held in place by a ball plunger Caution Be careful to not drop the unit when tilting it forward to remove it from the enclosure 3 Insert a thin blade from the front between the gasket and panel wall at the top center location to depress the latch 4 Tilt the RXi Display forward and remove it from the front of the enclosure Hardware Installation GFK 2898B 27 For public disclo...

Page 28: ...Notes 28 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 29: ... specified may present a high risk of fire or explosion Warning The battery may explode if mistreated Do not recharge disassemble heat above 100 C 212 F or incinerate Caution To avoid damage from electrostatic discharge adhere to the following precautions when opening the RXi Display 1 Wear a properly functioning antistatic strap and be sure that you are fully grounded Never touch any components i...

Page 30: ...ce the RTM chassis with interior lid on a static safe surface 4 Remove the four Phillips head screws that secure the interior lid to the RTM chassis and lift off the interior lid 5 Remove the RTC battery from the retaining clip Do not use any metallic item to remove the battery including screwdrivers knives pliers and such Caution Be careful to not bend the positive terminal clip on the battery ho...

Page 31: ...nd snapped into place 7 Replace and secure the interior lid using four Phillips head screws 8 Reconnect the internal power cable 9 Reattach the two RTM sections together without pinching the internal power cable and tighten the four captive screws to secure them 10 Carefully align the RTM to the display panel and push until the connector is seated 11 Tighten the six captive screws to fasten the RT...

Page 32: ...y from the display panel 3 Loosen the four captive screws that are holding the two RTM sections together and gently separate without stretching the internal power cable Disconnect the internal power cable and place the RTM section containing a circuit board with switch SW1 facing up on a static safe surface 4 Remove the tape covering SW1 if present and move the SW1 1 switch from the default Off po...

Page 33: ...the standards identified in Appendix A 2 Can be permanently connected while the system is running 3 Intended only for temporary connection 5 1 Input Power The RXi Display requires the following power input power connection To connect the dc power supply refer to the section Initial Startup 24 V dc 18 32 V range 65 W power supply Warning The power supply used should be a UL listed power source prov...

Page 34: ...ory 5e twisted pair cable between each node and a switch hub or repeater Attention For all three types shielded twisted pair STP cable is required to maintain CE compliance 10BASE T Two pairs of wire are used one for transmission and the other for receive 100BASE TX Two pairs of wire are used one for transmission and the other for receive 1000BASE T Four pairs of wire are used for simultaneous tra...

Page 35: ...RJ 45 female connector with the following pin assignments Attention Shielded cable is required to maintain CE compliance Serial RS 232 Port Pin Assignments RJ 45 Pin Signal Description 8 0 V 0 V 7 NC No connection 6 NC No connection 5 0 V 0 V 4 NC No connection 3 Rx Receive 2 NC No connection 1 Tx Transmit Connectors and Cabling GFK 2898B 35 For public disclosure ...

Page 36: ...yboard mouse serial communications or data storage device Attention Double shielded cable that complies with USB 2 0 is required Note These USB ports are defined as maintenance ports and are intended to be used only as temporary connections Pin Signal Pin 1 4 GND 3 Data 2 Data 1 Current limited 5 V dc 36 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 37: ... a 1 1 A self resetting fuse on the 5 V signal pin 9 5 6 Secure Digital Card Slot The RXi Display accommodates a user supplied Secure Digital SD card for auxiliary storage The SD card slot is a maintenance port that is intended to be used only as a temporary connection 5 7 Audio Jack For maximum cable length refer to the table Summary of Cabled Ports The RXi Display provides a Stereo OUT Mono Micr...

Page 38: ...Notes 38 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 39: ...ader driver VIA graphics driver IDT audio codec driver Custom GE IP drivers Qty 6 GE IP FpBtn driver for user defined buttons optional 6 2 Overtemperature Shutdown Recovery All Models If the RXi Display overheats it will shut down to protect critical components When this happens the Overtemperature LED will blink red and then shut off quickly while the entire unit shuts down The Power On Off LED t...

Page 40: ...Notes 40 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 41: ... Information Technology Equipment and Industrial Control Equipment Certification by Underwriter s Laboratories to UL CSA 60950 1 and UL 508 and CAN CSA C22 2 NO 142 1987 Electromagnetic Compatibility Directive 2014 30 EU Self declaration in accordance with European EU Directive Refer to the Declaration of Conformity located at http www ge ip com support Waste Disposal The Electronic Waste Disposal...

Page 42: ...munity EN 61131 2 Zone B ITE Immunity EN 55024 CISPR 24 Electrostatic Discharge EN 61000 4 2 8 0 kV Air 4 0 kV contact RF Susceptibility EN 61000 4 3 10 Vrms m 0 8 to 1 0 GHz 3 Vrms m 1 0 to 2 0 GHz 1 Vrms m 2 0 to 2 7 GHz Fast Transient Burst EN 61000 4 4 2 0 kV dc input 1 0 kV signal Surge Withstand EN 61000 4 5 0 5 kV dc input Line Line and Line Earth 1 0 kV signal Line Earth Conducted RF EN 61...

Page 43: ...rgy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Changes or modifications to this unit that are not expressly approved by GE Intelligent...

Page 44: ...Notes 44 GFK 2898B PACSystems 19 RXi Display For public disclosure ...

Page 45: ... ports 34 Ethernet media 34 F Features 9 Mounting 26 User 14 Federal Communications Commission FCC Notice 43 G Government regulations 43 Grounding 25 H Humidity 13 I Indicators 14 Ethernet 17 Ethernet media 34 Status 16 17 Initial Startup 20 Input power 33 Inspection 19 Installation 26 Display Panel 26 Guidelines 25 Guidelines for conformance 41 Hardware 25 IP address 22 IP Address 22 L LEDs Ether...

Page 46: ...tion port 35 Shock 13 Shutting Down the Computer 23 Specifications 11 19 RXi Display 12 Environment 13 General 11 Standards 41 EMC 42 Startup Initial 19 Intial 20 Status 17 Status Indicators 16 SW1 1 32 System Recovery 39 Drive failure 39 Overtemperature shutdown 39 T Temperature Ambient 13 Recovery 39 Tool less Installation 26 Touchscreen 10 U Upacking 19 USB Ports 36 User defined 16 V Video outp...

Page 47: ......

Page 48: ...Automation Controls from GE 1 800 433 2682 1 434 978 5100 www geautomation com GFK 2898B For public disclosure ...