24 2
INSTANT ZONE WITH CHIME ENABLED
A trip will create an alarm when the system is armed. When the control panel is disarmed
and the chime mode has been set, this zone will act as a chime zone.
25 2
FOLLOWER ZONE WITH CHIME ACTIVATED
This zone will be instant when the system is armed and no entry or exit delays are being
timed. It is delayed during entry and exit delay times. This zone will not bypass automatically,
even if enabled in segment 1 of location 23. When the control panel is disarmed and the
chime mode has been set, this zone will act as a chime zone.
26 2
24 HOUR, AUDIBLE, SUPERVISED, LOCAL
Creates an instant audible alarm, regardless of the arming state of the control panel. It will
display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This zonetype will
NOT be reported.
27 2
INSTANT ZONE FORCE ARMABLE
This zone creates an instant alarm whenever the system is armed. This zone is force armable
(see feature definitions, pages 5-11).
28 2
INSTANT ZONE ACTIVITY MONITOR ENABLED
This zone creates an instant alarm whenever the system is armed. It will send a report if the
zone activity time is reached without a change of state (see location 40, segment 11 and
locations 110-169).
29
INSTANT ZONE WITH END OF LINE RESISTOR DEFEAT
This zone creates an instant alarm whenever the system is armed. When the loop is closed,
the zone is ready. Opening of the loop means a faulted zone (see locations 110-169).
30 2
24 HOUR, MEDICAL, AUDIBLE, SUPERVISED
Creates an instant audible alarm, regardless of the arming state of the control panel. It will
display on the keypad (e.g. flashing zone LED’s, and changed READY LED). A medical report
will be sent to the CMS.
Note: all zone configurations are programmed for double end of line resistor
configuration, except for DAY ZONE, FIRE, 24H AUDIBLE SUPERVISED and END OF LINE
RESISTOR DEFEAT.
NX-4-EUR Installation manual
Page 48
02/07/06
Summary of Contents for NX-4-EUR
Page 2: ...NX 4 EUR Installation manual Page 2 02 07 06 ...
Page 92: ...CE DECLARATION NX 4 EUR Installation manual Page 92 02 07 06 ...
Page 93: ...NX 4 EUR Installation manual Page 93 02 07 06 ...
Page 94: ...NX 4 EUR Installation manual Page 94 02 07 06 ...
Page 95: ...NX 4 EUR Installation manual Page 95 02 07 06 ...
Page 96: ...NX 4 EUR Installation manual Page 96 02 07 06 ...
Page 97: ...NX 4 EUR Installation manual Page 97 02 07 06 ...
Page 98: ...NX 4 EUR Installation manual Page 98 02 07 06 ...
Page 99: ...NX 4 EUR Installation manual Page 99 02 07 06 ...