Segment 5
1 = On: Disables auto-bypassing of force armable zones at the end of the
exit delay
2
=
Reserved
3
=
Reserved
4
=
Reserved
5
=
Reserved
6
=
Reserved
7
=
Reserved
8
=
Reserved
Entry/Exit timers
LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Entry time 1
This is the entry time that will be used when a delay 1
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 2
Exit time 1
This is the exit time that will be used for all zones
designated as delay 1.
Valid entries are 10-255 seconds.
Segment 3
Entry time 2
This is the entry time that will be used when a delay 2
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 4
Exit time 2
This is the exit time that will be used for all zones
designated as delay 2.
Valid entries are 10-255 seconds.
Segment 5
Reserved
Segment 6
Reserved
NX-4-EUR Installation manual
Page 45
02/07/06
Summary of Contents for NX-4-EUR
Page 2: ...NX 4 EUR Installation manual Page 2 02 07 06 ...
Page 92: ...CE DECLARATION NX 4 EUR Installation manual Page 92 02 07 06 ...
Page 93: ...NX 4 EUR Installation manual Page 93 02 07 06 ...
Page 94: ...NX 4 EUR Installation manual Page 94 02 07 06 ...
Page 95: ...NX 4 EUR Installation manual Page 95 02 07 06 ...
Page 96: ...NX 4 EUR Installation manual Page 96 02 07 06 ...
Page 97: ...NX 4 EUR Installation manual Page 97 02 07 06 ...
Page 98: ...NX 4 EUR Installation manual Page 98 02 07 06 ...
Page 99: ...NX 4 EUR Installation manual Page 99 02 07 06 ...