NX-148E LCD Keypad
17
IV.
PARTITIONED SYSTEMS OPERATION
This system is
“
is not
“
partitioned.
If your system is multi-partitioned and the keypad resides in one partition, your
keypad will provide the status of the zones in your partitioning by using the screen
messages described earlier in this manual.
The Master Mode of operation allows you
to temporarily access any partition (providing your code is authorized) within the
system and to perform functions in other partitions. Read this entire manual to help
you understand the different screen messages that will be displayed from your
keypad.
NOTE
:
r
1
will
temporarily
access the Master Mode. The keypad will revert back
to its assigned partition 60 seconds after a keypress, or 10 seconds without a
keypress. Press [#] to exit this mode.
LIGHTS IN PARTITIONING MASTER MODE
ARMED
will illuminate if ALL partitions are armed.
READY
will illuminate if ALL partitions are "Ready". The
ready light
will flash if all
areas are Ready or Force armable.
FIRE
will illuminate if ANY one area has a Fire condition. The
fire light
will flash if
ANY area has a Fire Trouble condition.
POWER
will illuminate if the primary power is connected to the NX-8 control
panel. It will flash if the system has a low standby battery condition.
STAY
will illuminate if ANY area has the
stay light
on.
CHIME
will illuminate if ANY partition is in the "Chime" mode
.
EXIT
will illuminate if ANY area is timing an exit delay. It will flash if ANY area is in
the last 10 seconds of an exit delay.
BYPASS
will illuminate if ANY area has a zone bypassed.
CANCEL
will flash if ANY partition is in an abort delay time. If a code is entered
followed by the [
CANCEL
] key during or after an alarm report, the
cancel light
will
illuminate and remain constant until the central station has received the cancel
report.
SOUNDER
will sound if ANY area has the sounder on. This includes Entry delay,
Exit delay, Chime, and Alarm.
DISPLAYS IN THE PARTITIONING MASTER MODE
ARMED and READY STATUS
The LCD screen will display the Armed and Ready status of ALL eight (8)
partitions if any or all of the areas is armed or not ready.