NX-10 Expander Installation Guide
51
Version
A menu option that displays the current software version of the proximity reader.
X-10 Functions
A menu entry that groups X-10 device information and the functions for the selected NX-
1750 ProxPad.
The X-10 functions are linked to the access reader. It is possible to control X-10 devices
using the badge on the card reader. It is also possible to configure the actions that are
activated by each card action.
0 All units off
1 All lights on
2 On
3 Off All others
4 Dim
5 Bright
6 All lights off
Programming locations for the NX-1750
Location 0 Badge Functions (3 segments of binary data)
Location 0 is used to select the particular function(s) that are activated when a card is scanned. More
than one function may be selected. If more than one function is selected, they will execute in order
from function 1 to function 8.
Segment 1
: Single Badge (1 Beep)
A card is badged once. The buzzer sounds once. (Default function is
8
.)
Segment 2
: Double Badge (2 Beeps)
A card is badged and held at the reader for the duration of the Scan Time (Location 4, Segment 1).
The buzzer sounds twice. (Default function is
8
.)
Segment 3
: Triple Badge (3 Beeps)
A card is badged and held at the reader for the duration of 2 times the Scan Time (Location 4,
Segment 1). The buzzer sounds three times in total. (Default function is
8
.)
Segment 1
Single Badge Function
1
Send Code Entry function to the control panel
2 Arm
Away
3
Arm Stay mode
4 Disarm
5
Activate Aux/KeyFob Function 1 (see control panel events)
6
Activate Aux/KeyFob Function 2 (see control panel events)
7
Broadcast an X-10 function (see Location 1)
8
Send a Request to Exit (RTE) and activate the relay output. (Default is On.) Location 3,
Segment 2 must be programmed with a valid zone number for the RTE to be sent.
Segment 2
Double Badge Function
1
Send Code Entry function to the control panel
2 Arm
Away
3
Arm Stay mode
Summary of Contents for NX-10