Minimum system configurations for UL installations
The following requirements apply to residential fire, residen-
tial burglary, and commercial burglary installations.
• The NetworX NX-6V2 panel is necessary to initiate resi-
dential and commercial installations.
• At least one compatible keypad is needed for all applica-
tions.
• The AD10-12 bell and UL Approved bell-housing shall be
used for all applications.
• Commercial UL applications require the NX-003-C metal
enclosure. Supplied screws to be used.
• A minimum of two keypads is required for home health
applications, and each keypad must be set to a unique
address.
• The wireless devices are only UL listed for residential
applications.
• The DACT shall be enabled for all commercial burglary
applications.
UL requires that an alarm panel work for a minimum amount
of time during a power failure.
Table 6
lists the battery capac-
ities needed to meet time limits based on the current draw of
the panel and all attached devices.
Note:
Calculations are based on three 17 A batteries.
Specifications
WARNING:
Electrical codes will vary, depending upon
the country and city where the system is installed. It
is the installer’s responsibility to ensure that the
electrical installation is safe and conforms to all
applicable codes, laws, or regulations. Only
qualified persons should connect this device to the
main supply.
Table 6.
Battery capacities
Standby time
Total auxiliary
current
Standby battery
capacity
Alarm current
24-Hours
1.9 A
1.25 A
600 mA
51 Ah
34 Ah
17 Ah
600 mA
1 A
1 A
48-Hours
900 mA
600 mA
300 mA
51 Ah
34 Ah
17 Ah
1 A
1 A
1 A
72-Hours
600 mA
400 mA
200 mA
51 Ah
34 Ah
17 Ah
1 A
1 A
1A
WARNING:
Replace only with a Panasonic LC12V4BP
or Yuasa NP4-12 battery. There is a risk of explosion
if the battery is replaced with an incorrect type.
WARNING:
If separate power supplies are necessary
to accommodate additional devices, safety
standards require that each power supply be
prominently marked with adequate instructions for
removing all power from the unit.
CAUTION:
Observe polarity when installing a new
battery. Installing the battery backwards may cause
damage to the panel. Dispose of used batteries
according to the manufacturer’s instructions and/
or local government authorities.
Operating power
16.5 VAC 40 or 50 VA transformer
Auxiliary power
w/25 VA transformer
w/40 or 50 VA transformer
(MG Electronics part
number 22-156 for UL or
22-156-CN for Canadian
installations)
12 VDC regulated 500 mA
12 VDC regulated 1 A
Loop resistance
Standard loop
300 ohms maximum
Fuse
Type T 200 mA 250 VAC
Built in siren driver
Two tone (temporal and yelp)
Loop response
Selectable 50 mS or 500 mS
Operating temperature
32 to 120°F (0 to 49°C)
LED keypad
Current draw
Zones normal w/o sounder
Dimensions
130 mA max.
55 mA
6.4 x 4.0 x 1.1 in. (16.3 x 10.2 x 2.8 cm)
NX148E LCD keypad
Current draw
Without sounder
Dimensions
110 mA max.
75 mA
6.4 x 5.3 x 1.0 in. (16.3 x 13.5 x 2.5 cm)
Metal enclosure dimension
11.25 x 11.25 x 3.50 in. (28.58 x 28.58 x 8.90
cm)
Shipping weight
9 lb. (4.1 kg)
FCC
This device complies with part 15 of the FCC rules. Operation is subject to the
following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Complies with Part 68 FCC Rules.
ACTA (FCC) ID: GCQUSA-33408-AL-E
IC: 1175A-NXV2