Minimum system configurations for UL installations

The following requirements apply to residential fire, residen-
tial burglary, and commercial burglary installations.

• The NetworX NX-6V2 panel is necessary to initiate resi-

dential and commercial installations.

• At least one compatible keypad is needed for all applica-

tions.

• The AD10-12 bell and UL Approved bell-housing shall be 

used for all applications.

• Commercial UL applications require the NX-003-C metal 

enclosure. Supplied screws to be used.

• A minimum of two keypads is required for home health 

applications, and each keypad must be set to a unique 
address.

• The wireless devices are only UL listed for residential 

applications.

• The DACT shall be enabled for all commercial burglary 

applications.

UL requires that an alarm panel work for a minimum amount 
of time during a power failure.

 

Table 6

 lists the battery capac-

ities needed to meet time limits based on the current draw of 
the panel and all attached devices. 

Note:  

Calculations are based on three 17 A batteries. 

Specifications

WARNING:  

Electrical codes will vary, depending upon 

the country and city where the system is installed. It 
is the installer’s responsibility to ensure that the 
electrical installation is safe and conforms to all 
applicable codes, laws, or regulations. Only 
qualified persons should connect this device to the 
main supply.

Table 6.

Battery capacities

Standby time

Total auxiliary 

current

Standby battery 

capacity

Alarm current

24-Hours

1.9 A

1.25 A

600 mA

51 Ah

34 Ah

17 Ah

600 mA

1 A

1 A

48-Hours

900 mA

600 mA

300 mA

51 Ah

34 Ah

17 Ah

1 A

1 A

1 A

72-Hours

600 mA

400 mA

200 mA

51 Ah

34 Ah

17 Ah

1 A

1 A

1A

WARNING:  

Replace only with a Panasonic LC12V4BP 

or Yuasa NP4-12 battery. There is a risk of explosion 
if the battery is replaced with an incorrect type.

WARNING:  

If separate power supplies are necessary 

to accommodate additional devices, safety 
standards require that each power supply be 
prominently marked with adequate instructions for 
removing all power from the unit. 

CAUTION:  

Observe polarity when installing a new 

battery. Installing the battery backwards may cause 
damage to the panel. Dispose of used batteries 
according to the manufacturer’s instructions and/
or local government authorities.

Operating power 

16.5 VAC 40 or 50 VA transformer

Auxiliary power
     w/25 VA transformer
     w/40 or 50 VA transformer

(MG Electronics part 

number 22-156 for UL or 

22-156-CN for Canadian 

installations)

12 VDC regulated 500 mA
12 VDC regulated 1 A

Loop resistance
     Standard loop

300 ohms maximum

Fuse

Type T 200 mA 250 VAC

Built in siren driver 

Two tone (temporal and yelp)

Loop response

Selectable 50 mS or 500 mS

Operating temperature

32 to 120°F (0 to 49°C)

LED keypad
     Current draw
     Zones normal w/o sounder
     Dimensions

130 mA max.
55 mA
6.4 x 4.0 x 1.1 in. (16.3 x 10.2 x 2.8 cm)

NX148E LCD keypad
     Current draw
     Without sounder
     Dimensions

110 mA max.
75 mA
6.4 x 5.3 x 1.0 in. (16.3 x 13.5 x 2.5 cm)

Metal enclosure dimension

11.25 x 11.25 x 3.50 in. (28.58 x 28.58 x 8.90 

cm)

Shipping weight

9 lb. (4.1 kg)

FCC

This device complies with part 15 of the FCC rules. Operation is subject to the 

following conditions: 
1. This device may not cause harmful interference. 
2. This device must accept any interference received, including interference that 

may cause undesired operation. 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment. 
Complies with Part 68 FCC Rules.
ACTA (FCC) ID: GCQUSA-33408-AL-E
IC: 1175A-NXV2 

Summary of Contents for NetworX NX-6V2

Page 1: ...resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a smal...

Page 2: ...revious location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the prog...

Page 3: ...numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which form...

Page 4: ...eless sensor missing and restore 4 Wireless sensor low battery and restore 5 Expander trouble and restore 6 Fail to communicate 7 Zone activity monitor 8 Reserved Location 18 Custom communicator forma...

Page 5: ...d no entry or exit delay is being timed It is delayed during entry and exit delay times This zone automatically bypasses if enabled in segment 1 This zone type is used to enable the tamper on a wirele...

Page 6: ...operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 121575W NS4 1215W NS4 121575W AS 1215W AS 121575W Horn s...

Page 7: ...e only with a Panasonic LC12V4BP or Yuasa NP4 12 battery There is a risk of explosion if the battery is replaced with an incorrect type WARNING If separate power supplies are necessary to accommodate...

Page 8: ...are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3...

Reviews: