3

Loading factory defaults

To load factory defaults, enter program mode, enter the 
device address and number and then enter 

9, 1, 0, #

. The 

keypad beeps three times indicating that loading is in 
progress. The process takes about six seconds. You cannot 
exit the location until loading is completed.

Enrolling modules and keypads

The NX-6V2 automatically finds and stores all keypads, zone 
expanders, wireless receivers, and other modules connected 
to the data terminal into the NX-6V2 memory. This allows the 
modules to be supervised by the control panel.
To enroll the modules, do the following:
1.

Enter program mode and program the desired settings 
for each module.

2.

When you exit program mode, the NX-6V2 automatically 
enrolls the devices. The enrolling process takes about 12 
seconds, during which time the Service LED illuminates. 
If a speaker is attached to the NX-6V2, it clicks at this 
time. If a siren or bell is attached to the NX-6V2, it sounds 
for about one second. If the module is not detected, the 
Service LED illuminates.

Note:  

User codes are not accepted during the enrolling 

process. 

Quick start programming locations

For most routine installations, the quick start locations allow 
you to enable a majority of the options available with the NX-
6V2 (when communicating in Contact ID or SIA formats). The 
quick start locations include:

• Location  0  -  Phone  1
• Location 1 - Phone 1 account code
• Location 2 - Phone 1 communicator format
• Location 3 - Phone 1 dial attempts/backup control

Location 0 - Phone 1

Location 0 has 20 segments of numerical data. Use this loca-
tion to program phone 1. The default for each segment is 

14

.

• To program a delay of four seconds, enter 

13

 in the 

appropriate segment.

• To program tone dialing, enter 

15

 in the segment where 

tone dialing begins.

• If the entire number is tone dialing, enter 

15

 in the first 

segment.

• Enter 

11

 for a 

*

, and 

12

 for a 

#.

Location 1 - Phone 1 account code

Location 1 has six segments of numerical data. Use this loca-
tion to program the account code sent when phone 1 is 
dialed. The default for each segment is 

10

. Program a 

10

 in 

the segment immediately after the last digit of the account 

code. If the account code is six digits long, program all six 
segments. 

Location 2 - Phone 1 communicator format

Location 2 has one segment of numerical data. Use this loca-
tion to program the communicator format used to transmit 
to the receiver connected to phone 1. Refer to your central 
station receiver documentation to determine which format is 
compatible. 

Table 4

 describes the formats for this location. If 

you need a format other than those listed, review the over-
ride options described in 

Location 18 - Custom communicator 

format

 on page 4 to build the appropriate format. Program a 

15 

to create a special format (in addition to the entries in 

Location 18). The default is 

0

. If this location contains a 

0

, the 

built-in communicator is disabled and the NX-6V2 functions 
as a local-only control.

CAUTION:  

A call-waiting cancel on a noncall-waiting 

line prevents successful connection to the central 
station.

Table 4.

Communicator formats

Data

Format

Description

0

Local 

Communicator is disabled

1

Universal 4+2

Two-digit event code 1800 Hz transmit 

2300 Hz handshake double round parity 

40 pps 

a

2

3+1 fast (or 4+1)

One-digit event code 1900 Hz transmit 

1400 Hz handshake double round parity 

20 pps

3

Reserved

Reserved

4

Pager

Two-digit event code DTMF transmis-

sion 

5

3/1 or 4/1 slow

1800 Hz transmit 2300 Hz handshake 

double round parity 20 pps hex capa-

bility

6

3/1 or 4/1 slow 

1800 Hz transmit 1400 Hz handshake 

double round parity 20 pps hex capa-

bility

7

3/1 or 4/1 fast

1800 Hz transmit 2300 Hz handshake 

double round parity 40 pps hex capa-

bility

8

3/1 or 4/1 fast

1800 Hz transmit 1400 Hz handshake 

double round parity 40 pps hex capa-

bility

9

3/1 or 4/1 fast with parity

1800 Hz transmit 2300 Hz handshake 

single round parity 40 pps hex capa-

bility

10

3/1 or 4/1 fast with parity  1800 Hz transmit 1400 Hz handshake 

single round parity 40 pps hex capa-

bility

11

4+2 express

Two-digit event code DTMF transmis-

sion

12

4+2 fast

Two-digit event code 1900 Hz transmit 

1400 Hz handshake double round parity 

20 pps

13

Ademco contact ID

DTMF 

14

SIA

Frequency shift keys

15

Custom format

See 

Location 18 - Custom communi-

cator format

 

16

3/1 or 4/1 slow

Same as 5, but sends the alarm event 

code rather than the zone number

17

3/1 or 4/1 slow

Same as 6, but sends the alarm event 

code rather than the zone number

18

3/1 or 4/1 fast

Same as 7, but sends the alarm event 

code rather than the zone number

19

3/1 or 4/1 fast

Same as 8, but sends the alarm event 

code rather than the zone number

20

3/1 or 4/1 fast with parity

Same as 9, but sends the alarm event 

code rather than the zone number

Summary of Contents for NetworX NX-6V2

Page 1: ...resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a smal...

Page 2: ...revious location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the prog...

Page 3: ...numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which form...

Page 4: ...eless sensor missing and restore 4 Wireless sensor low battery and restore 5 Expander trouble and restore 6 Fail to communicate 7 Zone activity monitor 8 Reserved Location 18 Custom communicator forma...

Page 5: ...d no entry or exit delay is being timed It is delayed during entry and exit delay times This zone automatically bypasses if enabled in segment 1 This zone type is used to enable the tamper on a wirele...

Page 6: ...operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 121575W NS4 1215W NS4 121575W AS 1215W AS 121575W Horn s...

Page 7: ...e only with a Panasonic LC12V4BP or Yuasa NP4 12 battery There is a risk of explosion if the battery is replaced with an incorrect type WARNING If separate power supplies are necessary to accommodate...

Page 8: ...are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3...