Flush Mode: (Start-up Cycle) (6 minutes maximum)
The Flush Mode begins:
Every time the user plugs the icemaker in.
•
The interface is changed from
•
OFF
to
ON
.
When the icemaker is turned on after the
•
completion of the
CLEAN
cycle, or
On auxiliary drain pump models only, power
•
cycled off due to water touching the over
fi
ll
contact. This is often due to slow or blocked
drain, or a blocked vent hose.
When the power is applied or the icemaker is turned
ON
at the user interface:
Water valve
fi
lls 45 oz. Maximum
fi
ll time is 2
•
minutes.
Recirculation pump runs for 1 minute.
•
Reservoir drain pump is on for 20 sec., off for 20
•
sec., then on for 20 sec.
Water valve
fi
lls to the selected volume.
•
Maximum
fi
ll time is 2 minutes.
Enter freeze mode
•
Freeze Mode: (Ice-Making)
Note:
If the water level drops below the sensor
before 5 minutes, the control counts a Hung Slab.
If the water level sensor is not detected, the control
sets a 25-minute freeze time.
Time in this mode is dependent on the water
level in the reservoir. There is no minimum time.
The maximum time is 25 minutes. Compressor,
condenser fan, and recirculation pump are all
energized.
Water continues to recirculate until the water level
in the reservoir drops below a level determined by
the water level sensor. At this point, the control
terminates the freeze mode and initiates the
Harvest Mode.
Control Board Diagnostics
Harvest Mode
The time in this mode will be 2 to 17 minutes,
dependent on the condition of the evaporator
thermistor.
The compressor and hot gas valve is on for a
minimum of 1 minute.
Note:
There is a 4-min.
fi
xed cycle time if the
evaporator thermistor is disconnected or open.
Harvest Mode: Bin Not Full
When the bin thermistor reads greater than 36°F:
Reservoir drain pump is on for 20 sec., off 20
•
sec., then back on for 20 sec.
Measured water
fi
ll is requested. Compressor
•
and hot gas valve are on until: evaporator
thermistor reads greater than 52°F and more
than 1 minute, but less than 16 minutes have
passed; or after 4 minutes if the evaporator
thermistor is unplugged or open.
Harvest Mode: Bin Full
The time in this mode with the bin full will be a
minimum of 5 minutes. The mode continues as long
as the bin is full and the bin thermistor remains less
than 36°F.
Compressor and hot gas valve are on until the
evaporator thermistor is greater than 52°F and more
than 1 minute but less 16 minutes have passed;
or after 4 minutes if the evaporator thermistor is
unplugged or open.
Idle Mode:
Time in this mode is dependent on the temperature
at the bin thermistor.
Bin Not Full (Bin Thermistor Greater than 36°F)
The control sends a reservoir
fi
ll request and Freeze
Mode begins.
(Continued next page)