M
Millenium™ RO System by GE Osmonics
14693e - 31 Mar 03
5- 5
Troubleshooting
5.1
RO Fails to Run
1.
Power off.
a. Check position of inlet and pump switches.
b. Check power cord (plugged in).
c. Check outlet and circuit breaker/fuse panel for power with voltmeter.
d. Check fuses in RO.
2.
Improper line voltage.
a. Verify that line and equipment voltages are compatible.
3.
Loose electrical connections.
a. Check all wiring connections to verify solid connection.
b. Verify that plug is securely connected to outlet.
4.
Inlet water valve switch not activated.
a. Check position of switch.
b. Check switch with voltmeter.
c. Replace
switch.
5.
Power switch inoperative.
a. Assure inlet water valve is open.
b. Check switch with voltmeter.
c. Replace
switch.
6.
Pump motor inoperative.
a. Verify that voltage supply is correct and motor is wired for correct voltage.
Correct as necessary.
b. Motor thermal overload switch tripped (most motors have automatic internal
reset). Motor will restart when it cools approximately 10-15 minutes. Correct
reason for the overload.
c. Remove pump head and try restarting motor.
d. Replace motor.
7.
Pump inoperative.
a. Inspect pump and motor coupling for wear.
b. Clean any debris or liquid from connection area.
c. Replace
pump.
d. See 5.5.
5.2
RO Runs Intermittently
1.
Loose electrical connection.
a. Verify that all wiring connections are secure.
b. Verify that plug is securely connected to outlet.
Summary of Contents for MILLENIUM OSMONICS MILLENIUMTM REVERSE OSMOSIS...
Page 2: ......
Page 6: ...14693e D D 31 March 2003 This page intentionally left blank...
Page 24: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 1 18 General Information NOTES...
Page 36: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 3 5 5 System Operation NOTES...
Page 67: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 4 30 Routine Maintenance NOTES...
Page 80: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 5 13 Troubleshooting NOTES...
Page 85: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 6 4 Drawings Millenium RO Disinfect View...
Page 86: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 6 5 Drawings Millenium RO Flow Schematic...
Page 98: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 6 17 Drawings NOTES...
Page 105: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 7 6 Spare Parts List NOTES...
Page 106: ......