M
Millenium™ RO System by GE Osmonics
14693e - 31 Mar 03
5- 7
Troubleshooting
5.5
Low Pump Pressure
1.
No pressure develops above level of feed pressure.
a. Verify motor operation and water line connections.
b. Verify flush valve is in the operate position.
c. Verify (lower than normal) flow from product, if high see membrane problem.
d. Verify (lower than normal) flow from waste, if high check flush valve operation.
e. Pump damaged or worn out, replace pump.
2.
Pressure develops but does not achieve normal operating pressure.
A. Waste or product flow too high.
a. Check water temperature and flow rate.
b. Check quality of product water.
B. Faulty inlet pressure regulator.
a. Replace
regulator.
C. Pump adjusted improperly
a. Adjust pump at pump head and regulator.
D. Pump worn out or damaged.
a. Replace
pump.
5.6
Pressure Gauge Vibrates Erratically
1.
Air in gauge tubing.
a. Loosen tube fitting at gauge to bleed air.
2.
Obstruction in pressure gauge orifice.
a. Remove
obstruction.
3.
Product return check valve operation (Product Gauge Only)
a. Check and remove obstruction in return check valve.
b. Replace check valve.
4.
Faulty gauge.
a. Replace
gauge.
5.
Inlet regulator faulty.
a. Replace
regulator.
5.7
Excess Product Pressure (too high)
1.
Inlet pressure regulator improperly adjusted.
a. Decrease pressure regulator to adjust maximum product setting.
Summary of Contents for MILLENIUM OSMONICS MILLENIUMTM REVERSE OSMOSIS UNIT
Page 2: ......
Page 6: ...14693e D D 31 March 2003 This page intentionally left blank ...
Page 24: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 1 18 General Information NOTES ...
Page 36: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 3 5 5 System Operation NOTES ...
Page 67: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 4 30 Routine Maintenance NOTES ...
Page 80: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 5 13 Troubleshooting NOTES ...
Page 98: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 6 17 Drawings NOTES ...
Page 105: ...M Millenium RO System by GE Osmonics 14693e 31 Mar 03 7 6 Spare Parts List NOTES ...
Page 106: ......