43
Hard water leakage after
regeneration.
a. Improper regeneration.
b. Leaking of external bypass valve.
c. O-Ring around riser pipe damaged.
d. System capacity too low due to
incorrect resin volume setting
a. Repeat regeneration after making
certain correct regenerant dosage was
set.
b. Replace bypass valve. (Contact dealer).
c. Replace O-ring
d. Reset control and program resin volume
to correct setting
Control will not draw
regenerant, or intermittent
or irregular draw.
a. Low water pressure.
b. Restricted drain line.
c. Injector plugged.
d. Injector defective.
e. Valve disc B1 and/or B2 not fully
open.
a. Make correct setting according to
instructions, 25 psi dynamic pressure
minimum.
b. Remove restriction.
c. Clean injector and screen.
d. Replace injector and cap. (Contact
dealer).
e. Remove foreign matter from disc and
check disc for closing by pushing in on
stem. Replace if needed. (Contact
dealer).
Control will not regenerate
automatically.
a. AC adapter or motor not connected.
b. Defective motor.
c. Fouled or defective turbine.
d. Defective turbine cable.
a. Connect power.
b. Replace motor. (Contact dealer).
c. Clean or replace turbine assembly.
d. Replace turbine cable.
Control regenerates at
wrong time of day.
Controller set incorrectly.
Correct the time setting according to
instructions.
No conditioned water after
regeneration.
a. No regenerant in regenerant tank.
b. Injector plugged.
a. Add regenerant to regenerant tank.
b. Clean injector and screen.
Backwashes or purges at
excessively low or high
rate.
a. Incorrect drain controller used.
b. Foreign matter affecting valve
operation.
a. Replace with correct size controller
(Contact dealer).
b. Remove drain controller and clean.
Run out of conditioned
water between
regenerations.
a. Improper regeneration.
b. Incorrect resin volume setting
a. Repeat regeneration,
b. Reset control and program resin volume
to correct setting
Control displays 1 - x
(1 thru 4)
a. Control is in test mode
a. Press control keys in order from left to
right.