342-86400-445PS
Issue
4.0
October
2006
Page
76
Copyright
GE Multilin Inc. 2002
REN connected to line
The maximum Ringer Equivalent Number for each line (typically equals to the
max number of telephones paralleled) is 2 (two).
Ringing Supply
The Ringing Supply parameters for the 86445-32 2W FXS unit are:
70 Vac, 20 Hz, sinusoidal balanced ringing
Ringing Cadence
PLAR mode:
2 sec ON + 4 sec OFF
LS or GS mode:
Follows cadence received from far-end
Ringing Duration
In PLAR mode:
Configurable to 10 sec, 20 sec, 60 sec or Indefinite.
LS or GS mode:
Unlimited (driven by the incoming signaling)
Ring Trip
<
200 msec
Signaling States
The Signaling States for FXS mode and PLAR mode are given in the following
tables: